Electric boiler proterm instruction manual. Setting, adjusting the power of a gas boiler. Installation, connection and start-up of the boiler Proterm Panther

The well-known Slovak company Protherm has gained confidence due to the high quality and reliability of the equipment produced. Careful study of the needs of customers, trends in demand for various models manufactured devices allowed the company to gain a leading position in the market.

The company produces dozens of: floor and wall, and, with open and closed cells combustion. Double-circuit wall-mounted gas boilers Proterms, to which this article is devoted.

Description of the double-circuit boiler Proterm

Boilers that have a heating function utility water, are called double-circuit, because they heat water for two systems - a heating circuit and a hot water supply system (DHW).

The DHW system in such boilers, if necessary, can function separately from the heating system. This mode is necessary for supplying the house hot water in summer time.

Wall-mounted double-circuit models are presented in a wide range of capacities - from 11 to 30 kV, which allows the buyer to choose best option depending on the heated area.

AT wall boilers a mechanism is provided for the release of the combustion chamber from exhaust gases. This is done in two ways. The first is the forced removal of residual gases using a fan, such a combustion chamber is called closed. The second option - the gases are given the opportunity to independently leave the room through the chimney, this chamber is open.

All Proterm products are equipped with the most modern systems automatic control, management and protection.

Distinctive features

By installing a double-circuit gas boiler Proterm in your house, you will become the owner of a real home boiler room, which, in addition to regular functions, will provide your household and hot water.

The following are the main distinctive features line of gas boilers Proterm:

  • economy, ease of use;
  • a large selection of models - by price, power, functionality, protection capabilities;
  • price-quality ratio - one of the best among manufacturers of similar equipment;
  • high efficiency (more than 90%);
  • models are available with a built-in boiler.

Important! Gas boilers Proterm are adapted for Russian conditions- they can function normally even with reduced pressure of gas or water in the lines.

Gas boilers produced by Proterm during operation will not disappoint you and will justify the wildest expectations.

Model range of boilers Proterm

The range of heating boilers offered by Proterm is wide and varied. The product catalog includes:

  1. electric boilers;
  2. solid fuel, working on wood and coal;
  3. universal units that can run on gas and diesel fuel;
  4. high power industrial boilers;

The range of Proterm gas boilers includes two types: and. The company manufactures gas boilers in the range from small wall-mounted devices weighing 30 kg to heavy floor units, the most famous of which is the double-circuit gas boiler of the Proterm company model Medved 30 KLZ weighing 155 kg.

As for double-circuit wall-mounted devices, they are produced in 5 series:

  • Panther (Panther).
  • Jaguar (Jaguar).
  • Lynx (Rys).
  • Cheetah (Gepard).
  • Tiger (Tiger).

Each series includes several models that differ in power, performance, price and some other parameters. In particular, the devices of the Panther, Cheetah and Tiger series include models with both closed and open combustion chambers. A typical representative is a double-circuit gas boiler of the company Proterm Panther 25 KTV with a power of 25 kW, in which there is a device for the forced removal of exhaust gases from a closed chamber.

Specifications

The main technical characteristics, for ease of comparison and speeding up the search for the necessary information, are summarized in Table 1.

Model Panther Jaguar Cheetah Tiger Lynx
Characteristic 25 KOV, 25 KTV, 30 KTV 11 JTVs, 24 JTVs 11MOV, 11MTV, 23MOV, 23MTV 12KOZ, 12KTZ, 24KOZ, 24KTZ 18/25 MKV 25/30 MKV
The combustion chamber T-closed O-open closed T-closed O-open T-closed O-open closed
RH temperature, °C 35-85 30-85 30-83 45-85 30-85
DHW temperature, °C 38-60 30-64 38-65 40-60 30-64
Expansion tank OV, l 7,0 7,0 5,0 8,0 8,0
expansion

DHW tank, l

2,0 5,0
DHW capacity, l/min up to 17.0 up to 10.7 up to 11 up to 12.6 up to 14.2
Natural gas consumption kg/h 2,84 – 3,44 2,73 1,41 – 2,84
Consumption liquefied gas, kg/hour 2,08 – 3,21 1,9 0,91 – 2,08
Consumption of natural gas DHW cubic meters / hour 2,73 1,39-3,08
Consumption of liquefied gas DHW, kg/hour 1,02 1,02-2,26
Consumption of natural gas RH m3/hour 1,39 2,73
Consumption of liquefied gas OB, kg/hour 0,55 1,02
Storage tank, l 45
Weight, kg 34 – 41 29 – 30 31 – 34 70 – 71 35 – 36
Dimensions, mm 800х338*440 700x280x410 740x310x410 900x410x570 700x280x390
Price, thousand rubles 45 – 53 27 – 32 34 – 39 50 – 130 54 – 56

Abbreviations: OV - heating water, DHW - hot water supply.

Deciphering the code in the model name:

  1. the two-digit figure corresponds to the rated power input in kW;
  2. the first letter - in combination with the third indicates the model;
  3. the second letter is the type of combustion chamber: O - open, K, T - closed;
  4. the third letter is the boiler type: V, Z - double-circuit, O - single-circuit.

In addition to the parameters indicated in the table, all wall-mounted double-circuit boilers have a number of other characteristics. In particular, they have the following protection systems:

  • safety valve to discharge the coolant when the pressure in the system rises;
  • protection circulation pump from jamming;
  • protection water pipes from freezing;
  • gas control - stops the gas supply to the burner if the flame suddenly goes out;
  • air outlet - getting rid of the trapped air from the heating system;
  • protection of the boiler against overheating with a thermostat.

The electronic control system for gas boilers performs the following functions:

  1. microprocessor control;
  2. device status control;
  3. regulation of indoor air temperature;
  4. display of current temperature readings and fault codes.

Service center maintenance

Every year, preferably before the first start-up after the summer break, it is recommended to invite a specialist from a certified service organization to inspect and test the boiler. During a preventive inspection, the condition is checked gas burner, power setting, cleaning burner nozzles and heat exchangers. A particularly important part of the inspection is to check the operation of the emergency thermostat and the combustion chamber thermostat.

Attention! When cleaning the nozzles of a gas burner, in no case should they be allowed to change their inner diameter!

Boiler maintenance by the user

Cleaning the casing of the unit without removing the protective cover. Must be carried out after disconnecting the device from the network. Power supply is allowed only after complete drying.

The water pressure in the heating circuit must be checked weekly. If necessary, carry out make-up after the unit has cooled down below 400°C.

It is necessary to regularly, at least once every three months, check the tightness of the connections of the chimney system, the cleanliness of the filter and the sump and remove dirt if necessary.

If a gas leak is detected, the device must be switched off immediately, the gas valve closed and a specialist service organization called. It is not recommended to repair the unit yourself. For example, the instruction manual for the Gepard wall-mounted double-circuit gas boiler manufactured by Proterm does not recommend trying to fix the malfunctions on your own, so as not to lose the company's warranties.

If it is not possible to connect to the gas network, and solid fuel heating not available, then alternative way providing the house with heat becomes an electric boiler. This article will introduce readers to the Proterm Skat electric boilers, as well as instruct them on how to launch them.

Electric boilers Proterm Skat

This single-circuit equipment is made in a wall-mounted variation. It is possible to connect a water heater. Most models three-phase mains connection required, but 6 kW and 9 kW models can be operated from 220 V. Selecting the required temperature level hot water and heating occurs with the help of a display, which, when adjusted, helps to control the operation of the equipment. Also, control is carried out using a thermostat or an outside temperature sensor.

To create a certain level of warmth, the parameters are adjusted individually. Power supply is controlled remotely from the tariff meter. For household needs you can install units of 24 kW and 28 kW in cascade.

Protherm Skat has:

  • double-sided pump;
  • expansion tank;
  • safety valve;

Also, the Protherm boiler can be connected through a voltage stabilizer. Electric boiler in action has a slow start, that is, for two minutes it "accelerates" and its power is minimal. Heating elements are protected from overload, their work is uniform, this is achieved by the possibility of setting the rhythm (1.2 or 2.3 kW).

Electrical Protherm boilers The slope is distinguished by its low weight (only 34 kg) and convenient dimensions, thanks to which it is possible to carry out installation on almost any area. The operation of the boiler is reliably protected by several functions:

  • pump blocking protection;
  • a pressure sensor that monitors the level of water pressure;
  • frost protection;
  • protection against valve blocking and freezing of the water heater (when connecting a boiler).

If errors occur in the operation of the boiler, automatic diagnostics occur, ending with the display of the results in the form of a code. The deciphering of the codes is given in the instruction manual for the product.

Advantages and disadvantages of Protherm Skat electric boilers

Proterm Skat has a number of advantages over other types of heating:

  • does not harmful emissions into the atmosphere, because has no combustion products, so this type of heating can be called environmentally friendly;
  • an electric boiler is an affordable type of heating. It is used where it is not possible to connect to the mains gas or can become an alternative form of heating;
  • does not need systematic maintenance, unlike, for example, gas or solid fuel models;
  • silent operation;
  • there is a heat level regulator;
  • able to adapt to domestic water of poor quality;
  • resistant to voltage drops;
  • equipped with several types of protection.

Along with the advantages, there are some disadvantages:

  • electric boiler Protherm Skat needs to be connected through a stabilizer;
  • not able to perform its work when the mains power is turned off.

Consumer reviews

Consumers note that Protherm Skat provided an opportunity where gas connection was problematic or even impossible. With the stable operation of the power grid, many refuse to connect gas, saving considerable amounts of money. In addition, the electric boiler is used in parallel with the gas unit, connecting them to a single heating system. This find allows significant savings on resources, alternating them with each other during the heating season.

If you connect a water heater to Protherm Skat, consumers will have the prospect of using hot water. Many note the perfectly designed design of the boiler, which fits well into any interior of the room. It can be successfully installed in living rooms, thanks to its silent operation, it will not cause increased attention to itself.

The disadvantages are that when using only a boiler powered by electricity, when it is turned off, there is no alternative options heating. Therefore, before making a purchase of a Protherm electric boiler, you should make sure that there are no problems with electricity. Experts recommend use a voltage stabilizer, to ensure the normal operation of the Protherm Skat boiler.

In addition, increased energy consumption by the electric boiler causes negative emotions the population, as the payment of bills hits the pocket. If we compare the costs of gas and electric heating, then the Protherm electric boiler is a little more expensive, with identical heating parameters. From the foregoing, we can conclude that this electrical equipment is chosen by those who do not have the ability to connect to the mains gas, as well as those who care about environment and sees it as a source of ecological consumption.

How to put the Protherm Skat boiler into action?

To start the boiler, follow the instructions below.

When the pressure is reduced, the “bar” light starts flashing on the display. To correct the situation, water should be added to the system. If in this case the pressure decreases, then you need to contact a specialist.

If you want to stop the operation of the Protherm boiler for a long time, then you need to disconnect it from the power supply and turn off the taps. If you need a stop at winter period, then water must be drained from the system to prevent freezing.

How to take care of the Protherm electric boiler? Do not use abrasive or chemical substances. It is better to wipe the surface of the case with a damp cloth, then dry the surface.

Any malfunctions are shown on the display with an error code. Code numbers are located and deciphered in the product passport.

If serious problems occur, such as the heat exchanger is frozen or water is dripping from it, it is forbidden to turn on the electric boiler to the power supply. It is necessary to wait for a specialist who will diagnose and make a quality repair. Parts can only be replaced with original spare parts.

So, dear readers, you got acquainted with an alternative type of heating Protherm Skat. When gas and solid fuel out of reach or you are an adherent of cleanliness, an electric boiler can be a good help.

The gas boiler Protherm (Proterm) is produced by the well-known company Protherm, founded in Slovakia more than a quarter of a century ago. The model range of this manufacturer is characterized by successful combination heating power levels and energy efficiency indicators.

Model range of Protherm boilers - single-circuit and double-circuit

Gas equipment Proterm is produced by a European manufacturer in several modifications, which allows you to choose the optimal in terms of functionality, as well as a practical and most convenient model in operation.

wall type

Wall-mounted gas equipment has undeniable advantages, including compact dimensions, external aesthetics, excellent performance properties, the ability to adapt to functioning with different energy carriers by means of standard nozzle replacement, as well as economy.

  • "Panther". Inexpensive model with two heat exchangers and water heating. A modern heating device with the possibility of functioning in a closed type system. It has reliable frost protection, automatic shutdown of gas supply and pump control.

Inexpensive option heater in the Protherm line

  • "Jaguar". A budget option equipment that does not have a winter / summer mode. Double-circuit unit with a closed type of combustion chamber and control by means of handles.

A simple model with the minimum required set of functions

  • "Cheetah". Double-circuit turbocharged boiler with a power of 11–23 kW and a closed type of combustion chamber. Even low-power models are capable of heating 10–11 liters of water in one minute. wall fixture, in which the movement of the heat carrier is carried out forcibly.

Turbocharged boiler with high efficiency

  • "Tiger". Differs neat appearance, informative LCD display and very simple control. There is a possibility of programming for different modes of operation or operation in the automatic "comfort" mode. It is possible to automatically control the combustion process, it is distinguished by a special ignition system.

Compact equipment with different operating modes

Main characteristics of the boiler

floor type

Floor single-circuit and double-circuit boilers have several advantages that make this type of equipment in demand among consumers. It is impossible to ignore the high performance indicators, the maximum efficiency of heat transfer, economical fuel consumption, wide functionality and guaranteed durability.

  • "Bear". The high-quality cast-iron heat exchanger makes the unit durable and very reliable. The model has a winter-summer mode and convenient traction control. It has automatic control of the combustion process and is distinguished by a special ignition system.

Cast iron heat exchanger ensures long-term operation of the boiler

  • "Buffalo". Easy to use and durable boiler with high efficiency, able to work on different types fuel. Very powerful unit with a high degree of reliability.

Powerful equipment that can run on different types of fuel

The main characteristics of the Bizon model

Floor standing boiler with reliable heat exchanger

Main characteristics of the model

Stationary heating gas boiler

The main characteristics of the model Bear KLOM17

Gas boiler device Proterm

Various modifications have individual features of the device.

The manufacture of boilers using low-temperature cast iron contributes to the effective minimization of heat losses. A feature of the design of heating appliances of the brand "Proterm" is also an unusual, fairly environmentally friendly way of burning fuel.

The main components of the gas heating equipment presented:

  • ignition system;
  • burner;
  • heat exchanger.

The heat source is represented by a burner flame in which gas is burned, and a heat exchanger is responsible for heating the heat carrier. The gas supply process is regulated by a thermostat, while the combustion products, represented mainly by water vapor and carbon dioxide, are removed through the chimney system.

Proterm boilers are used for heating and hot water supply

How to connect and set up

Basic conditions for installing a heating gas equipment from the manufacturer "Proterm":

  • installation of the boiler and the necessary auxiliary equipment is carried out in accordance with the design documentation, taking into account the requirements of SNiP and the manufacturer's recommendations;
  • installation of equipment is carried out in a room specially designed for these purposes, and with a special modification of the unit - only in well-ventilated outbuildings;
  • the process of installation and commissioning is carried out by specialists who have completed a course in the installation and maintenance of gas equipment;
  • elimination of any malfunctions of the boiler is carried out by a service organization authorized by the manufacturer of heating and hot water equipment;
  • independent installation work entails the deprivation of the consumer of the guarantee for the unit and its repair;
  • when unpacking the heating equipment, the completeness of the delivered boiler and the compliance with the type of fuel used must be checked.

Before proceeding with the installation, you need to carefully read the attached instructions, and during the installation process, all the recommendations given in the accompanying documents must be observed. Markings on equipment must not be damaged or removed.

Standard connection and configuration technology gas boiler:

  • fixing the unit to the wall is carried out by means of screws with appropriate gaskets;
  • branch pipes for connection should not be loaded with a pipe heating system, hot water supply system or gas supply elements;
  • the installation dimension of the connection of pipes, including their height and the required distance from inlet to outlet, must be strictly observed;
  • the placement of the hydraulic group is carried out on the lower part of the gas equipment, and the system is necessarily equipped with a filling valve and safety and relief valves;
  • in conditions of exceeding the maximum pressure inside the system, steam or water is discharged from the safety and relief valves;
  • connecting the unit to the heating system implies the ability to perform a full range of preventive maintenance and repair work;
  • water is supplied to the heating system through a filling valve, and drain device it is used to lower the pressure indicators or to partially drain the heat carrier;
  • full-fledged drain and fill functions have special outlets installed in dedicated areas of the heating system;
  • the pressure of hot water supply to the equipment must exceed the same indicators in the heating system;
  • in the “Filling” valve position (hydraulic group), the system operation must be monitored by means of a boiler pressure gauge;
  • opening of fittings is made counterclockwise, and closing - strictly clockwise.

Boiler equipment service items under the warranty do not include measures represented by deaeration and adjustment of the expansion tank.

Video: Connecting the Proterm boiler

Video: Setting up Protherm equipment

Brief instruction manual

Competent adjustment of Protherm gas boilers provides optimal temperature conditions in rooms of different purposes and areas. Among other things, the regulation of the automation of such equipment helps to increase the efficiency of the unit, and also makes its operation reliable and safe. Modern automation solves problems:

  • opening and closing valves in the gas supply system;
  • the process of starting the unit in automatic mode;
  • installed or emergency shutdown of boiler equipment;
  • adjustment of the flame level in the burner by means of a temperature sensor;
  • display on the screen of indicators of air temperature, the level of heating of the coolant and other parameters.

Instructions for setting up a gas boiler:

  • connecting the thermostat to a temperature sensor fixed in the room and setting the required values ​​​​allows you to obtain a comfortable temperature regime for heating;
  • installation of a thermostatic valve on the supply pipes in front of heating radiators helps to change the cross-sectional area of ​​\u200b\u200bthe pipe section and easily carry out the process of regulating the temperature of the heat carrier;
  • the first start of the system at the limiting temperature allows the used coolant to freely enter the tank, which contributes to its maximum filling;
  • the increase in efficiency is facilitated by the timely removal of scale and soot, as well as the control of the absence of air in the system and the installation of a draft limiter;
  • regulation of pressure indicators is carried out using special valve regulators, and in order to increase the pressure, a circulation pump is installed;
  • the reduction in the power of the boiler burner is carried out automatically through the service menu, and the power is adjusted to increase by installing additional radiators or replacing existing ones with the most powerful models;
  • many units are characterized by full performance at a pressure of 1.5 atm., And normally this value is 0.3 atm. lower than in heating system;
  • a slight decrease in the pressure level in the unit is restored during a standard restart;
  • automatic selection of the operating mode of the gas boiler helps maintain the desired temperature level even with a long absence of consumers in the room.

The process of first turning on the boiler is accompanied by its short and vigorous operation after the unit is fully connected to the heating system, which makes it easy to check the correct installation of the boiler equipment and the full functioning of the heating.

Common errors and malfunctions

Some of the most common malfunctions of Proterm gas boilers can be completely eliminated on their own, but fixing the most complex mistakes must be entrusted to the professionals of the service center.

Error/fault Code/designation Solutions
Reduced pressure level in the unit or heating system F0 Check the operation of the pressure sensor, make sure that there are no cable damages and the integrity of the boiler control board
No flame in the burner F1 Check the operation of the emergency thermostat and ignition transformer, make sure the gas supply and the integrity of the gas valve, restart
Rapid overheating of the gas boiler F3 Eliminate clogging in the water filter and pump, check the operation of the heat exchanger, replace the anti-freeze mixture
An open in the temperature sensor circuit F4 Check the resistance readings on the sensor, make sure that the cables connecting the control panel and the sensor are intact
Input signals are not recognized F7 Make sure the information panel is working, check the panel connectors
Opening the NTC sensor circuit and grounding the DHW boiler F8 Ring the connections, disconnect and reconnect the elements or completely replace the sensor
The presence of a short circuit on the traction sensor F15 Dismantle and clean the terminal connections, clean the tubes, if necessary, replace the assembly completely
Low pressure inside the heating circuit F22 Top up the coolant to the required level, make sure the system is completely tight and there are no leaks
The rapid increase in the temperature of the coolant F24 Replace insufficiently productive pumping equipment and get rid of air in the system.
Failed initial ignition F28 To eliminate the error / malfunction, it is necessary to involve the specialists of the service center
Fan frost protection activation F33
Repeat pressure sensor error F75

Modern heating equipment from a manufacturer from Slovakia, which category includes single- and double-circuit gas boilers Protherm, is distinguished by high reliability and model diversity. These kind and inexpensive boilers of European quality from the “middle class” are quite deservedly popular and are invariably in demand by domestic consumers.

When buying any heating equipment, the user receives instructions. It describes all the points that relate not only to the installation of the unit, but also to its operation. Boiler Proterm Skat 9 kW is no exception. Of course, for some reason the instruction was lost, then it will not work to start heating the house. After all, the electric boiler must be properly configured. There are certain rules for the installation and operation of an electrical unit. They must be observed. Otherwise, the equipment will not work correctly.

The advantage of the electric boiler Proter Skat

The Proterm Skat unit has a number of advantages. Such heating equipment has become a good alternative to gas heating appliances. The popularity of Proterm Skat boilers is increasing every year. After all, such units are ideal for heating houses that are not connected to the main gas pipeline. Electric boilers of this modification are simply indispensable for country cottages with occasional or seasonal residence.

Among the advantages of such units, the following should be highlighted:

It is worth noting that Proterm Skat electric boilers have proven themselves during their existence as economical and safe heating devices.

Installation Features

Boilers Proterm Skat 9 kW are supplied with all necessary fasteners and elements. Besides the kit includes an instruction that describes the process of connecting and setting up the unit step by step. It is worth noting that models that differ in power have exactly the same principle of installation, operation, and configuration.

Before installing heating equipment Proterm Skat, it is necessary to coordinate all work with electrical distribution services.

Electric boilers Proterm Skat with a power of 9 kW can be connected to a conventional 220V power supply. Installation of such heating equipment is carried out using a mounting plate. Such a unit does not have certain restrictions on the choice of installation location. Of course, there are some requirements - it is necessary Free access for service, maintenance, adjustment and repair of heating equipment.

How to install

The Proterm Skat electric boiler is connected to the pipe system using branch pipes. The heater is connected in such a way that, in the event of malfunctions during operation, the coolant can be freely drained without affecting the entire system. Additional valves allow you to fill the system with coolant and drain it. also, in order to exclude freezing of water in houses with seasonal residence during cold periods, experts recommend removing the coolant completely from the system before the temperature drops.

The Proterm Skat boiler is connected to the mains through a power line connected separately. The network cable is connected to the terminals, which are located in the lower corner of the case. All screws on the connectors must be carefully tightened. A boiler with a power of 9 kW can be connected to a single-phase network.

How to use the Proterm Skat boiler

The operation of the Proterm Skat electric boiler does not cause any particular difficulties. After all, such heating equipment is equipped with systems for control and regulation. In order for the device to start working, you need to do just a few simple steps:

  1. Plug the unit into the mains.
  2. On the control panel of the heating equipment, select the required temperature mode.
  3. Adjust the power of the unit.
  4. Make finer adjustments temperature regime.
  5. If necessary, change the pressure level in the system.

After the done manipulations, you must press the "Start" button. That's all, the Proterm Skat boiler is ready for work. During the first few days of operation, it is worth monitoring the operation of the unit and, if necessary, adjusting the temperature regime. This will identify some problems in the operation of the unit caused by the presence of air jams in the system.

Electric boilers are in demand among owners of suburban housing, residential cottages and other non-gasified buildings. They are characterized by good functionality and allow you to heat any buildings that are not connected to gas mains. Their typical representative is the Proterm electric boiler - this is a device from a well-known manufacturer, characterized by high build quality and decent performance.

We decided to devote this review to Protherm electric boilers. In it we will tell:

Equipment from such a well-known manufacturer really deserves special mention, so we will tell you everything we know about Proterm boilers.

Features of Proterm electric boilers

By installing such an electrical unit in your household, you are doing great choice. Rather than buying equipment from dubious brands, it is better to overpay a little and take a really worthwhile thing from a well-known manufacturer - the performance of the entire system depends on the quality of the boiler used. Moreover, Protherm has extensive experience in the production of electric heating equipment.

There is only one the lineup- Skat.

Heating a home that is not connected to gas mains is always a big problem. Electric boilers existing on the market are either high in cost or cannot boast of sufficient functionality. In this case, you always pay attention to small and neat gas models, working in automatic mode and not cluttering up the space. Protherm is ready to offer owners of suburban housing similar solutions, but powered by electrical network.

Protherm electric boilers are a unique solution with proper efficiency. They are installed both in residential and non-residential buildings, regularly generating heat. They are presented by a single model range called Skat - there are samples with a thermal power of 6 to 28 kW to choose from. Thanks to this, they can heat rooms up to 280 square meters. m.

What are good?

  • Simple single-circuit design - if you like simple and reliable equipment, you will definitely like the products of this brand;
  • Wide power range - it is possible to choose a device that is suitable in terms of power and at its price;
  • High efficiency - efficiency, according to the manufacturer, is 99.5%. This means that almost all of the consumed electricity is converted into heat, without significant losses;
  • Absolutely silent operation - even if the equipment is in the bedroom, it will not interfere with a good night's sleep;
  • The presence of precise temperature control - create a comfortable and cozy atmosphere in your home;
  • The presence of universal models - they can operate from single-phase and three-phase networks with a voltage of 220 or 380 V;
  • Easy installation - you can handle the installation yourself, without resorting to the help of specialists.

Prices range from 37,900 to 47,000 rubles - this is the official price from the manufacturer as of April 2016. In some other stores, it may differ up or down (usually up). But nothing will stop you from buying a Proterm electric boiler in the official online store - this is the most economical and reliable option.

The cost of equipment may seem high, but Protherm is always responsible for the quality of its products.

Specifications and appearance

The Proterm electric boiler will fit into any interior thanks to its small sizes and wall placement.

As befits good equipment from a well-known brand, Proterm electric boilers are enclosed in neat small-sized cases. Thereby they can fit into any interiors even the most sophisticated ones. Case dimensions - height 740 mm, depth - 310 mm, width - 410 mm (dimensions are identical for the entire Skat model range). Inside we will find everything that is needed for the operation of the heating system:

  • Circulation pump;
  • Automatic air vent;
  • Expansion tank for 7 liters.

No need to suffer with the installation of the strapping - just connect the pipes and radiators, fill the system with coolant, after which you can start testing.

Models with a power of 6 kW and 9 kW can operate from both single-phase and three-phase networks. More powerful are three-phase. The equipment is not afraid of power surges and does not overload the network - a stepwise increase in power is provided here. The maximum current in the circuit during the operation of heating elements is up to 50 A. The maximum coolant pressure in the system is 3 atm, the temperature is up to +85 degrees.

When connecting Protherm electric heating boilers to the electrical network, make sure that the cross section of the wires corresponds to the power consumption.

The layout of the supply lines of electric boilers Proterm, as well as their dimensions.

Protherm electric boilers are endowed with convenient control panels. They are LED indicators and liquid crystal displays. Self-diagnostic systems are provided - error codes are displayed on built-in screens. Thermostats are used to create a comfortable atmosphere. Security systems are represented by an overheating sensor, frost protection, pressure sensor, safety valve and anti-blocking system of the circulation pump.

An interesting functionality is the ability to connect external storage boilers, which are purchased separately.

Popular Models

The Protherm Skat 9 KR 13 electric boiler is the most purchased. It is used for space heating up to 90 sq.m. m.

As we have already said, Protherm electric boilers are represented by the only Skat line. Therefore, all equipment has similar characteristics, differing in electrical power and current consumption - all other data are identical, up to dimensions and weight. As for the most popular models, then they are designs with a capacity of 9 kW, 12 kW and 21 kW.

In addition, the Skat range includes models with a capacity of 6 kW, 14 kW, 18 kW, 24 kW and 28 kW - the maximum heating area depends on the power (heat losses and the possibility of connecting a boiler must be taken into account in the calculations).

Instructions for use

When installing and configuring the device, you must follow the safety rules and use protective equipment. The boilers are mounted in a dry place, away from flammable structures, emergency exits, air conditioners and other electrical appliances. Do not install in places where water can get on the equipment. Also, operation in freezing rooms is not allowed.

Mount the equipment on solid walls, taking into account the weight. Heating pipes must fit evenly and without distortions. Connection to the mains is carried out using wires suitable for the cross section, directly to electrical panel, through additional automatic RCDs. For impact protection electric shock equipment must be grounded. You also need to make sure that the supply voltage meets the established standards. External components and modules are connected in accordance with the instructions.

Table for calculating the required wire cross-section and fuse rating depending on the power

Ideally, the installation should be carried out by certified specialists, but if you follow the instructions and follow the safety rules, nothing bad will happen.

During the operation of the equipment, it is necessary to monitor the temperature in the system and respond to possible mistakes. If the equipment is working properly, users can only set the desired temperature. The choice of the temperature of the heating circuit and the temperature in the external storage boiler (if any) is made using the buttons on the control panel - the control of parameters and errors is carried out using the LCD display.