Gas boiler Ariston dimensions. Double-circuit gas boiler Ariston: advantages and disadvantages. Gas boiler Ariston Genus EV - video

The Italian company Ariston produces high-quality and durable equipment for hot water supply and heating. gas boilers pleasantly combine economy with comfort and environmental friendliness.

General characteristics of gas boilers Ariston

Price segments of boilers and their quality features

Gas boilers Ariston in terms of cost can be attributed to:

  • middle price segment CLAS EVO;
  • premium price segment GENUS EVO.

The average cost of models can be represented as:

  • from 29 000 rub. — CLAS EVO SYSTEM;
  • from 38 560 rub. — CLAS EVO;
  • from 41 160 rub. — GENUS EVO;
  • from 52 000 rub. — CLAS PREMIUM EVO SYSTEM;
  • from 58 000 rub. — GENUS PREMIUM EVO SYSTEM;
  • from 60 800 rub. — CLAS PREMIUM EVO;
  • from 65 200 rub. — GENUS PREMIUM EVO.

Boilers CLAS EVO are produced as single-circuit and double-circuit. Equipped with an LCD display.

GENUS EVO boilers are equipped with a backlit matrix display. Thanks to the additional personalization of the display, it is possible to configure the necessary information about the boiler parameters.

Combining functions of boilers

Many characteristics of Ariston gas boilers are inherent in the equipment of any price segment. Boiler menu of any price level presented in Russian.

The presence of the AUTO function provides automatic adjustment of power in accordance with temperature changes inside and outside. All boilers Ariston have noise and heat insulation.

The company gives a guarantee of 2 years for traditional boilers and 3 years for condensing boilers. Any Ariston boiler is easy to install, operate and service. The many features of the boilers make them safe, for example:

  • pumping air from the heating circuit;
  • semi-automatic make-up;
  • protection against scale and freezing;
  • blocking the circulation pump.

Remote control of work is possible. In the event of a malfunction, the diagnostic system reports what has happened. You can send a command to restart the boiler.

Features of condensing boilers

Simple wall models of Ariston gas boilers cost 16,000 - 32,000 rubles. The cost of condensing boilers ranges from 40,000 to 45,000 rubles.

This price is explained by their high environmental friendliness, significant efficiency, profitable operation. Their work is characterized by high efficiency and low maintenance costs.

Condensing boilers are equipped with a modulating pump and fan depending on the load level. As a result, energy is saved and noise is reduced.

The specifics of the double-circuit models Ariston

The presence of a double-circuit mechanism means the combination of heating and supply functions hot water. The Ariston group of double-circuit gas boilers usually includes three series:

  • genus,
  • egis,
  • Clas.

Genus

Boilers are the most functional and outwardly attractive. Ariston Genus. They are equipped with primary and secondary heat exchangers with high performance.

The fan has a smooth speed control. The boilers are equipped modern system controls with a large LCD display.

Egis

Egis boilers are attractive in design and compactness. They feature an intelligent control system and high efficiency. The Ariston Egis boiler is equipped with two heat exchangers, a unique hydraulic group and a digital display.

It can operate under conditions of reduced gas pressure, low pressure and water consumption. Safe operation is ensured by many functions, including self-diagnostics. There are filters, mechanical water purification.

Heats an area of ​​260 m 2 . Weighs 30 kg. Price - 23,000-28,000 rubles.

Clas

The Ariston Clas gas boiler has won fame as the most practical and economical of all Ariston boilers. It has two securely separated heat exchangers. The combustion chamber is turbocharged and closed.

The boiler is equipped with a high power pump, expansion tank, digital display.

Heats an area of ​​230 m 2 . Weighs 30 kg. Price - from 26,000 rubles.

Gas boilers with a heat output of 24 kW

Ariston gas boilers are available with various thermal outputs, starting from 24 kW (the best choice). Here are some models with this power:

1. Wall-mounted gas boiler Ariston BS II 24 CF has compact dimensions, low weight, two separate heat exchangers, original hydraulic group. Its individual advantages:

  • adaptation to reduced pressure gas and water;
  • normal operation at low temperatures outside (up to minus 52 degrees); protection against scale and freezing;
  • self-diagnosis;
  • durability of the burner with protection against frequent switching on;
  • mechanical water filters, etc.

The cost is 24,100 rubles.

2. Gas wall mounted Ariston boilers Class System are different:

  • adaptation to Russian conditions by gas;
  • open combustion chamber and natural exhaust;
  • temperature control;
  • "Comfort Plus" function, providing hot water desired temperature in 5 seconds, automatic shutdown in an hour and switching on at the first water intake;
  • smoothly adjustable fan;
  • high power pump;
  • automatic diagnostics with digital display;
  • the ability to connect a programmable clock.

The cost is 27,300 rubles.

3. Wall-mounted gas boilers of the Ariston Egis Plus brand with traditional heating technology, auto diagnostics, built-in circulation pump, have almost the same characteristics. expansion tank with a capacity of 8 liters.

The cost is 22500 - 27600 rubles.

What are the buyers saying?

A wide variety of models of Ariston gas boilers opens up a wide field of choice for consumers. Ambiguous and customer reviews.

Andrey, 32 years old. Put parents in private house double-circuit wall-mounted boiler Ariston BS II 24 FF. The model is compact and, most importantly, economical. They began to pay less for heating by almost 700 rubles. per month.

Vladimir, 28 years old. About the wall-mounted gas boiler Ariston Egis Plus 24 FF. Put in the country instead of a water heater. Spent 27,000 rubles. This money is not a pity, because everything suits. The house is big, and the boiler too. The heat is retained for a long time, and in the morning it heats up quickly.

Anatoly, 34 years old. For three years I used the ARISTON CLAS 24 FF boiler. Everything was wonderful. Suddenly out of order recently circulation pump. Can't find a new one. They say to order for a decent amount. Until I know what to do.

Ivan, 36 years old. On the advice of friends, I bought and installed an Ariston boiler with a closed firebox for a house of 170 sq. m. The first heating season went well. In winter, the house became warmer than before. Many friends bought the same and do not complain.

Dmitry, 38 years old. We forked out for Ariston Genus 24 CF. I have been using the boiler for three years. During this time, not a single malfunction. I am completely satisfied with the stability and efficiency, I generally keep quiet about the level of comfort. True, sometimes after a long bath, the radiator cools down a little, but then the temperature is restored.

Ariston gas boilers comply with European environmental standards due to reduced emissions of harmful substances into the atmosphere and environmentally friendly packaging without foam.

The purchase of this equipment is an economical and reliable solution for the conditions of a city apartment or a country house.

Each owner of his house tries to make it as cozy and comfortable as possible. To achieve this, it is worth thinking about installing an Ariston double-circuit wall-mounted gas boiler, which will help solve problems with heating a dwelling. The device is very useful in that it will provide heat both in an apartment and a private house up to 500 m².

Also, a gas wall-mounted boiler of a double-circuit type Ariston will allow you to quickly heat water for instant use. In this case, a person does not have to connect a boiler, which will require additional investments and a separate place for installation.

Descriptions of the double-circuit boiler Ariston

Today, there are many interesting models on the market for gas boilers. This is quite convenient, since everyone will be able to choose a device that is most suitable for the price, type, characteristics and installation method. Dual circuit wall boilers Aristons gained their popularity due to rare situations with their malfunction, as well as silence during operation, which is very important for maintaining a calm atmosphere in the house.

One of the most important components in all gas boilers is the burner, in this case it can be modulating or conventional. The first option is more popular than the second. When using it, the entire system will be regulated automatically, without human intervention. In this case, the power of the installed heating equipment depends on the temperature indicators.

The burner is also divided into 2 types:

  • open;

It is the safest, since it does not involve the entry of combustion products into the room in case of emergency. Also in this case, the owner may not worry about building a chimney. It is necessary to bring a special coaxial pipe to the closed burner; it can always be brought out in any accessible place.

An open-type Ariston boiler, in any case, requires a chimney to bring combustion products outside. Also, do not forget about natural traction. Air will enter the system from the living quarters, so it will have to be constantly ventilated.

coaxial pipe used in closed system combustion, the good thing is that it is made of 2 layers. One is necessary for the withdrawal of combustion products, and the other will ensure the entry fresh air inside the boiler. Thus, the owner of the equipment does not have to constantly ventilate the room and worry about natural draft. The room will always have enough oxygen.

Distinctive abilities

According to reviews of gas wall-mounted double-circuit boilers Ariston, they have 4 distinctive features useful for their owners:

  1. All models of this company are equipped with automatic protection systems.
  2. The presence of a water pump, which is necessary for the constant circulation of water through the pipes.
  3. Possibility to choose a model with an expansion tank. With its help, automatic pressure control will occur inside the heating system.
  4. Ariston equips its equipment various types ignition. It can be automatic, which will greatly facilitate the life of the owner of a particular boiler. Otherwise, each time the unit is started, a person will need to press a special button.

What are the advantages of Ariston gas boilers

Recently, the popularity of the Ariston brand has increased significantly due to high-quality gas boilers, and this is not in vain. operates silently and consumes as little fuel as possible. This will allow the owners of the unit to save on utility bills and, at the same time, provide comfort and warmth to the house.

The client will receive quality device, which provides round-the-clock water supply and heating of the house, even with a large area up to 500 square meters. Also, do not forget about the durability of the service of each boiler. The terms indicated in the guarantee are much more modest than they actually turn out to be. In terms of dimensions, the equipment is much more compact than other brands, which means that it can be installed absolutely anywhere, even in a small apartment with limited space.

Specifications

Almost all gas boilers from the Ariston brand have a capacity of 15 to 30 kW. Thus, each client will be able to choose the necessary indicators for the size of his apartment or house. It is also worth noting other distinguishing characteristics of such gas equipment:

  • with maximum efficiency, boilers have a high level of efficiency;
  • all wall-mounted boilers have Russian instructions and designations on the equipment itself, so citizens do not have problems with controlling the unit;
  • most models from this manufacturer are able to perfectly cope with water in the system and low pressure;
  • special attention to this equipment should be given to those people in whose houses power surges often occur. Ariston boilers can easily cope with such jumps in the network;
  • All models are very easy to operate. To start using the boiler, you do not need to study the instructions for a long time, all the features of operation are intuitive and accessible even for those who install such a unit for the first time.

In some cases, the boiler cannot simultaneously heat water and provide sufficient space heating, this applies to budget models. In this case, a person needs to think about installing an additional boiler.

Note! If we talk about expensive units, they have a special display that shows different characteristics, including the temperature inside the boiler and outside. This is very convenient in terms of introducing the necessary characteristics for the correct operation of the equipment.

Operating instructions for gas boilers Ariston

Before purchasing an Ariston gas boiler, you need to understand that if the buyer does not understand its installation, it is better to contact experienced specialists and entrust all the work to them. After all, even at the maximum detailed instructions not the fact that the case will end successfully. In this case, there is every chance of damaging the equipment, after which you will have to call repairmen, and this will result in additional costs.

It is very important to keep children away from the equipment. To do this, after, it is necessary to have a conversation with them and explain in an accessible language that nothing can be twisted and put on the unit, only an adult should do this. If the family leaves, for example, on vacation, after the boiler is turned off, it is also necessary to shut off all pipes for the supply of gas and water. Only after that the equipment is disconnected from the network.

If a display is provided on any model, all indicators that it displays must be strictly controlled. It can display malfunctions or deviations from normal operation that occurred during the heating process.

One of the most important points in the instructions for gas equipment is safety. Before connecting the boiler, you need to familiarize yourself with it first.

What are the types of wall-mounted boilers Ariston

All Ariston boilers are divided into 3 series. They have different technical indicators and functions, namely:

  1. Clas - this series refers to more bulky and powerful devices for heating residential premises. They are equipped exclusively with special regulators that automatically regulate the gas supply. This is necessary to save fuel, which is very convenient in terms of the cost of public utilities and with frequent business trips of the owner of the house.
  2. Genus. These are the most innovative and multifunctional models of Ariston gas units. They have more features than other boilers from this manufacturer. Together with the equipment itself, the buyer will receive such additional accessories, as a fan, necessary for smooth speed control, as well as heat exchangers, primary and secondary. All devices from the Genus line are distinguished by the presence of a large liquid crystal display. It will display all the characteristics that correspond to the operation of the boiler at the moment.
  3. Egis. Units from this series have small size and attractive appearance, which earned them great popularity among owners of small apartments. The device will fit well into any interior. An important feature of these boilers is that, for their size, they have a fairly high level of efficiency and low fuel consumption, which is controlled by an intelligent control system.

Because of what the wall-mounted boiler may be faulty

The main reasons for the malfunction of Ariston gas boilers include the following:

  • During the maintenance of the burner adjustment or control units, specialists made mistakes.
  • Failed installation.
  • Buying a fake, which is distinguished by low-quality components.
  • Lack of sufficient air supply.

Conclusion

When buying one of the Ariston wall-mounted gas boilers from the seller, you need to check the availability of all the necessary documentation, which

confirm that the equipment corresponds to the manufacturer. Only in this case, problems with the device will arise very soon.

On this page you can find and download instructions for Ariston gas wall-mounted boilers in pdf format.

      Gas wall-mounted boilers Ariston series GENUS 24 FF, GENUS 28 FF, GENUS 36 FF, GENUS 24 CF, GENUS 28 CF. User manual. Language: RU, RO | pdf 786.93 Kb

      Gas wall-mounted boilers Ariston of the GENUS 24 CF, GENUS 28 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.09 Mb

      Gas wall-mounted boilers Ariston GENUS 24 FF, GENUS 28 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.07 Mb

      Gas wall-mounted boilers Ariston GENUS 24 FF, GENUS 28 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 5.05 Mb

      Gas wall-mounted boilers Ariston of the GENUS 24 CF, GENUS 28 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 3.14 Mb

      Gas wall-mounted boilers Ariston of the GENUS 36 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 893.17 Kb

      Gas wall-mounted boilers Ariston GENUS 36 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.00 Mb

      Gas wall-mounted boilers Ariston series GENUS 24 CF, GENUS 28 CF, GENUS 24 FF, GENUS 28 FF, GENUS 35 FF. User manual. Language: RU, RO | pdf 7.32 Mb

      wall single-circuit boilers CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF. Installation and maintenance instructions. 2008 | pdf 4.71 Mb

      Gas wall-mounted single-circuit boilers CLAS System 15 FF, CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF, CLAS System 15 CF, CLAS System 24 CF, CLAS System 28 CF. User manual. 2008 | pdf 1.24 Mb

      Gas wall double-circuit boilers EGIS 24 CF. Installation and maintenance instructions. 2008 | pdf 1.01 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF. Installation and maintenance instructions. 2008 | pdf 1.24 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF, EGIS 24 CF. User manual. 2008 | pdf 497.92 Kb

      Gas wall-mounted boilers Ariston series BS 24 FF, BS 24 CF. User manual. Language: RU, PL | pdf 439.96 Kb

      Gas wall-mounted boilers Ariston BS 24 CF series. Installation and maintenance instructions. Language: RU, PL | pdf 1.86 Mb

      Gas wall-mounted boilers Ariston BS 24 CF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.05 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.08 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series. Installation and maintenance instructions. Language: RU, PL | pdf 2.33 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series. User manual. Language: RU, UA, RO | pdf 228.38 Kb

      Gas wall-mounted boilers Ariston BS II 15 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.71 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1012.93 Kb

      Gas wall-mounted boilers Ariston BS II 24 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.88 Mb

      Gas wall-mounted boilers Ariston BS II 24 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1018.39 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1005.51 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.38 Mb

      Gas wall-mounted boilers Ariston series BS II 24 FF, BS II 24 CF. User manual. Language: RU, UA, RO | pdf 246.76 Kb

      Gas wall-mounted boilers Ariston series CLAS 24 FF, CLAS 28 FF, CLAS 24 CF. User manual. Language: RU, RO | pdf 661.98 Kb

      Gas wall-mounted boilers Ariston CLAS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.28 Mb

      Gas wall-mounted boilers Ariston of the CLAS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1005.77 Kb

      Gas wall-mounted boilers Ariston of the CLAS 24 FF, CLAS 28 FF series for heating and hot water supply. Installation and maintenance instructions. Language: RU, RO | pdf 2.78 Mb

      Gas wall-mounted boilers Ariston of the CLAS 24 FF, CLAS 28 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.13 Mb

      Gas wall-mounted boilers Ariston series CLAS B, CLAS B Premium: CLAS B 24 CF, CLAS B 24 FF, CLAS B 30 FF, CLAS B Premium 24, CLAS B Premium 35. Instruction manual. Language: RU, PL, CZ, RO, HU | pdf 2.52 Mb

      Gas wall-mounted boilers Ariston CLAS B 24 CF series. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 7.20 Mb

      Gas wall-mounted boilers Ariston of the CLAS B 24 CF series for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.09 Mb

      Gas wall-mounted boilers Ariston of the CLAS B 24 FF, CLAS B 30 FF series for heating and hot water supply. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 8.84 Mb

      Gas wall-mounted boilers Ariston of the CLAS B 24 FF, CLAS B 30 FF series for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.15 Mb

      Ariston gas wall-mounted boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF series. User manual. Language: RU, RO | pdf 373.49 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF. Installation and maintenance instructions. Language: RU, RO | pdf 1.87 Mb

      Gas wall-mounted boilers Ariston of the CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 987.40 Kb

      Ariston gas wall-mounted boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.60 Mb

      Ariston gas wall-mounted boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 990.97 Kb

      Ariston gas wall-mounted boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO SYSTEM 15 CF, CLAS EVO SYSTEM 24 CF series. User manual. Language: RU | pdf 306.18 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF. Installation and maintenance instructions. Language: RU | pdf 2.33 Mb

      Gas wall-mounted boilers Ariston of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF series for heating and hot water supply. Passport. Language: RU | pdf 946.87 Kb

      Gas wall-mounted boilers Ariston series EGIS PLUS 24 FF, EGIS PLUS 24 CF. User manual. Language: RU, RO | pdf 204.57 Kb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.29 Mb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 973.91 Kb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 934.35 Kb

      Gas wall-mounted boilers Ariston of the EGIS PLUS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 1.69 Mb

      Gas wall-mounted boilers Ariston series GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF, GENUS EVO 24 CF, GENUS EVO 30 CF. User manual. Language: RU, RO | pdf 446.18 Kb

      Gas wall-mounted boilers Ariston of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 991.20 Kb

      Gas wall-mounted boilers Ariston of the GENUS EVO 24 CF, GENUS EVO 30 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1019.57 Kb

      Gas wall-mounted boilers Ariston series GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF. Installation and maintenance instructions. Language: RU, RO | pdf 2.72 Mb

      Gas wall-mounted boilers Ariston GENUS EVO 24 CF, GENUS EVO 30 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.19 Mb

In the assortment of Ariston today there are 3 models of double-circuit gas boilers for providing residential buildings with heating and hot water supply. For rooms with an area of ​​less than 200 m2, the BS II model is offered, and for areas of 200-350 m2, BS II, EGIS PLUS and CLAS B.

The advantage of the devices is the cost of generating heat compared to all other types of boilers. The disadvantage is the need for a central gas supply system and the constant availability of power.

Gas boilers are suitable for heating and hot water supply of residential apartments and country houses, being a cheaper alternative to central heating.

General characteristics of boilers

Familiarity with the characteristics is necessary for right choice device models:

  • Execution - floor or hinged. The hinged version has more compact dimensions, but also a smaller generated thermal power. Differences in functionality in modern models no.
  • type of combustion chamber. An open chamber draws air from the room, and emits flue gases through the chimney. The closed chamber can take in air and exhaust exhaust gases one at a time. coaxial pipe. For installation in an apartment, it is preferable closed chamber combustion.
  • Thermal power of each circuit in kW. The area of ​​the heated room depends on the parameter. Estimated calculation of 1 kW per 10 m 2 of the room.
  • Efficiency factor (COP). Characterizes the efficiency of the device for the transfer of energy obtained by burning gas. The higher the efficiency, the less fuel is required to heat the water.
  • The temperature of the heat carrier in °C and the range of its regulation. It is necessary to select a device that provides the desired temperature.
  • Circuit capacity in liters per hour. When evaluating this parameter, it is necessary to take into account the average water consumption for hot water supply, it may be advisable to use a storage structure with an installed one.
  • Availability of protection and comfort control functions, a wide range of operating modes.


Model line

BS II - wall-mounted gas boiler for heating and hot water supply in apartment buildings. The boiler has a compact design, low weight and two reliable separate heat exchangers:

BS II 15FF BS II 24FF BS II 24 CF
The combustion chamber closed open
11-15 11-25,8 11,2-25,8
11-28 11-27 11-27
89,6 93,8 91,9
89,3 93,6 91,2
35-85
DHW circuit temperature, °С 36-60
13,6
9,7
Weight, kg 30
Price, rub 36 500 42 000 39 000

Model CLASB has a wall-mounted version and a built-in boiler of 40 liters made of stainless steel. The device is designed for high water consumption in the DHW circuit, combining the functions of a storage and instantaneous water heater.

The model is equipped with a digital display for comfortable control:

CLAS B 24 CF CLAS B24FF CLAS B 30FF
The combustion chamber open closed
Thermal power (heating circuit, kW 11-25 11-25,8 13-31,3
Thermal power (DHW circuit), kW 11-27 11-27 13-31,3
Efficiency at 100% thermal power, % 91,9 93,8 93,6
Efficiency at 30% of thermal power, % 91,2 93,6 93,2
Heating circuit temperature, °С 35-82
DHW circuit temperature, °С 40-65
Productivity of the DHW circuit when heating water by 25 ° C, l / min 22,8 25,2
Capacity of the DHW circuit with water heating at 35 °C, l/min 16,3 18
Weight, kg 52 55
Price, rub 84 000 87 700 90 000

EGIS modelPLUS available in 24 kW version and is a worthy continuation of the BS II series.

The boiler is wall-mounted and equipped with a comfortable digital control panel, the price does not exceed BS II:

EGIS Plus 24 CF EGIS Plus 24FF
The combustion chamber open closed
Thermal power (heating circuit, kW 11,2-25,8 11-25,8
Thermal power (DHW circuit), kW 11,2-25,8 11-25,8
Efficiency at 100% thermal power, % 91,9 93,8
Efficiency at 30% of thermal power, % 91,2 93,6
Heating circuit temperature, °С 35-85
DHW circuit temperature, °С 36-60
Productivity of the DHW circuit when heating water by 25 ° C, l / min 13,6
Capacity of the DHW circuit with water heating at 35 °C, l/min 9,7
Weight, kg 30
Price, rub 35 500 39 900

Instrument selection

When choosing a device, you must be guided by the following criteria:

  • The area of ​​the heated room in m 2. It is necessary to choose a boiler based on 1 kW of heat output per 10 m 2 of the room. At the same time, it must be understood that this perfect option and taking into account the heat loss of the dwelling, the average annual air temperatures at the installation site and the radiators used, it is required to introduce a correction factor. For a preliminary assessment, we advise you to use any online calculator that takes into account the above factors, and also introduces corrections for the location of the walls (windward or not), ceiling height, type of windows.
  • Need for hot water. For large consumption, it is reasonable to choose the CLAS B model with an integrated boiler, which is more economical.
  • Location of the boiler. For water heaters with an open combustion chamber, room equipment is required supply ventilation because the combustion air comes directly from the room. Since devices with an open combustion chamber are designed to remove combustion products through a natural draft chimney, it is necessary to provide for the installation location of the chimney and chimneys.

    IMPORTANT! It is not allowed to pass chimneys through structures made of combustible material.


Gas boiler device

Boiler malfunctions

Most of the malfunctions that occur can be prevented at the boiler installation stage. Here is a list of the main malfunctions, their causes and measures to prevent the failure of the device:

  • Failure of the control board. It occurs, as a rule, due to poor quality of electricity - power surges, frequent power outages. To prevent breakdowns for this reason, it is necessary to provide. For a private house, a good solution would be to install a backup diesel generator and an automatic transfer system. Need to protect your device circuit breaker, power it through a separate cable line and securely ground it.
  • Deterioration of the passport characteristics of the device, expressed in undercooling of water or reduced performance during heating. It is associated with the presence of contaminants in the water, excessive water hardness. In both cases, deposits appear on the heat exchanger tubes, which impede the heating and passage of water in the system. To solve the problem with contamination, it is necessary to install a filter, and when using water with a high calcium content, it is recommended to heat the water to 45-50 ° C.
  • Frequent stops due to insufficient water pressure. The fault is detected by the instrument and triggers a protective stop. BEFORE purchasing the unit, find out the parameters of the water supply network and make changes to it if the pressure is below 1.5 bar. If the pressure is higher than 6 bar, consider installing a pressure reducing valve. If the parameters of the main network are normal, then turn off the boiler and check the system for leaks.
  • Frequent stops on the smoke exhaust system. BEFORE installing the unit, calculate and install the gas ducts and chimney providing the required traction.
  • Frequent stops due to lack of air. Before installing the appliance, equip the room with a supply ventilation system.
  • Non-compliance of the operating modes with the declared ones, non-compliance of the coolant with the specified parameters. The main reason is incorrect commissioning and incorrect device settings. Careful reading of the instructions often solves the problem. If necessary, a qualified person should be called in to commission and instruct the device.
  • When choosing a model, please contact the company which will pick necessary equipment based on your requirements;
  • Trust the installation and commissioning of the device qualified specialist;
  • Read the instructions carefully for operation;
  • Do not neglect periodic preventive examinations and maintenance of equipment;
  • In case of any frequent malfunction, turn off the boiler and call a qualified specialist;
  • Trust repair and supply of spare parts only certified organization.

Installation of a gas boiler and its connection to the system is the most effective method organization of heat supply in a house or apartment. Control services have special requirements for the premises. To install a gas boiler, it is necessary to carry out a number of preparatory work.

The installation of equipment is preceded by measures to adapt the premises in accordance with applicable requirements. They are detailed in the Technical Specifications issued by Oblgaz or Gorgaz. This is true for the organization of heating on liquefied or natural gas. But usually, in the latter case, the issuance of an official permit is neglected, which can lead to a serious fine and a ban on the use of the existing heat supply system.

The document regulating the requirements for the premises for the installation of gas heating boilers is developed on the basis of the following regulations:

  • SNiP 31-02-2001. Designed for control construction works and building design.
  • SNiP 42-01-2002. Describes the rules for organizing gas distribution systems.
  • SNiP II-35-76 in the latest edition of 2012. They are guided by the choice of boilers and similar gas equipment.
  • SNiP 42-01-2002 and SP 41-104-2000. Needed to comply with standards when designing autonomous sources of heat supply.

It can take a long time to study these documents. In fact, about 20% of their content is devoted to the organization of domestic heat supply using gas boilers. To avoid wasting time, we recommend that you familiarize yourself with useful excerpts from regulations.

Requirements for the organization of the boiler room

If the boiler power does not exceed 200 kW, any built-in rooms of the house can be used as a boiler room. These include basement and basement rooms. For boilers up to 30 kW, the minimum room volume must be at least 7.5 m³. Accordingly, for equipment from 30 to 60 kW - 13.5 m³, more than 60 kW - from 15 m³. You also need to take into account other characteristics of the boiler room.

These include the following requirements:

  • square air vent for gas boilers up to 30 kW - 0.02 m², from 30 to 200 kW - 0.025 m² ();
  • the distance from the protruding parts of the equipment to the walls is regulated by the manufacturer;
  • the presence of a transom or window to reduce the concentration of gas in case of leakage, providing a three-fold replacement of air in 1 hour;
  • natural and artificial lighting of the room, the ratio of window area to volume - 0.03 m² per 1 m³;
  • if the boiler room is located on the first or basement floor, they must equip a separate passage, the door must open outward;
  • ceiling height - not less than 2.5 m;
  • a refractory material is installed on the walls in the boiler installation area, the fire resistance limit of which is at least 0.75 hours.

Placement of heat supply components is free. The main requirement is that nearby objects should not interfere with repair or maintenance work.

Characteristics of the kitchen for the installation of a gas boiler

The power of most gas boilers rarely exceeds 30 kW. This makes it possible to install them in the kitchen of a house or apartment. This is also done by agreement of the controlling organizations. Many of the above rules apply for this case, but given the specifics of the premises, there are additional ones. for a boiler with an open combustion chamber, three air exchanges are provided within one hour;

  • the wall at the installation site must be made of non-combustible materials, the minimum distance from it to the boiler is 10 cm;
  • for wall models, the distance to the ceiling is from 15 cm, to the side wall - from 10 cm;
  • when installing boilers with an open combustion chamber, it is forbidden to install an exhaust hood.
  • In practice, preparing the kitchen will require much less effort. Thus, ventilation can be provided by installing a lattice or a gap of 0.02 m² in the lower part of the door.

    These rules are not "ultimate truth". The main document for preparing the boiler room for the installation of gas equipment will be the Technical Conditions.