How to turn on the heating on the ariston boiler. How to connect a gas boiler Ariston: recommendations for installation, connection, configuration and first start. Ariston Genus boiler combustion products removal system

Maintenance and start-up of the gas boiler Ariston Uno

Preparing the wall-mounted gas boiler Ariston Uno for work

If the Ariston Uno 24 mi boiler is installed in an apartment, it must be checked that all regulations regarding air intake and ventilation of the room are observed (in accordance with current regulations).

Periodically check the water pressure with thermomanometer "L" and check (when the system is cold) that it is between 0.2 and 1.3 bar.

If the pressure is below the minimum value, it must be restored using the filling valve located at the bottom of the boiler.

When the pressure reaches 0.7 bar, close the valve. If the pressure drop occurs very frequently, there may be a water leak in the system. In this case, the leak must be repaired.

Switching on procedure - Press the "C" button. The electronic device will ignite the burner without any manual intervention, depending on the heating or cooking command hot water.

If after 10 seconds the burner does not ignite, the safety devices of the Ariston Uno 24 mi boiler will block the gas outlet and the red light diode “G” will light up.

To turn on the boiler in this case, press the button "B". If blocking occurs again, check that the gas cock is open.

Heating regulation - It is possible to regulate the temperature of the water in the heating circuit using knob "A", setting the pointer between the minimum and maximum values. The temperature may vary between 45°C and 80°C.

Control using a chrono-thermostat - If a chrono-thermostat is installed, it is recommended to keep the heating temperature set at the maximum value using knob "A" for a higher efficiency of the Ariston Uno 24 mi boiler.

Technical and service maintenance wall-mounted gas boiler Ariston Uno 24 mi

Checking the tightness of the hydraulic system of the boiler, replacing the gaskets and restoring the tightness.

Leak test gas system boiler, replacement of gaskets and restoration of tightness.

Visual inspection of the general condition of the boiler.

Visual check of combustion and cleaning of the burner.

After checking, disassemble and clean the combustion chamber.

After checking, clean the injectors.

Visual inspection of the primary heat exchanger: checking the condition of the plates; cleaning smoke channels heat exchanger;

Adjustment of the normal gas flow: consumption at ignition, at partial and full load.

Checking the functioning of security systems: overheating; on excess of working pressure;

Checking the functioning of the security system of the gas part of the Ariston Uno boiler: protection in the absence of a flame (flame sensor); safety of the gas valve;

Checking electrical connections.

Monitoring the operation of the DHW circuit (checking performance and outlet temperature).

Determination of characteristics of combustion products.

General check of the functioning of the boiler.

Monitoring the health and correct location of the smoke detector. If necessary, replace with a smoke detector with similar characteristics.

Removing the casing

To approach the internal elements of the Ariston Uno 24 mi boiler, you must:

Unscrew the screws located at the bottom of the boiler;

Turn the mounting plates outward;

Pull the lower part of the front panel forward until the central latches come out and remove towards the top.

When removing the casing and turning the control panel, access to the internal elements of the boiler is opened.

Initial start-up of the boiler Ariston Uno 24 mi

When you turn on the device for the first time:

Make sure that: electrical connections and grounding are made correctly and a two-pole switch is installed with a minimum gap of open contacts of at least 3 mm; the plug of the automatic air vent of the heating system is loosened; pressure in the heating system
below 0.7 bar; gas cock closed

Unlock circulation pump by unscrewing the plug on the front of the pump housing and turning the pump shaft with a screwdriver.

Connect the power supply to the boiler by pressing the button “C” and set the handle “A” between the minimum and maximum marks to activate the “winter” mode. Thus, the circulation pump will turn on; after 7 seconds, a lockout will be activated due to the absence of a flame.

Leave the Ariston Uno boiler in this state until the end of air bleeding.

To remove air pockets, loosen the plug of the deaerator of the circulation pump; re-bleed the air from the radiators; on the a short time open the hot water tap;

Check the pressure in the heating system, if it has dropped, open the filling valve and bring the pressure to 0.7 bar;

Check that the flue gas system is working properly.

Make sure the required shut-off valves open.

Open the gas cock and check the tightness of all connections, including the main burner (the gas meter must not record the gas flow). In any case, check the tightness of the connections with soapy water and repair gas leaks, if any.

Press the "B" button to unlock the ignition. The igniter will ignite the main burner; if this does not happen with first time, repeat the same operation.

Check the value of the minimum and maximum gas pressure on the main burner and adjust the pressures.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Proterm Panthera Proterm Skat Proterm Bear Proterm Cheetah Evan
Ariston Egis Teplodar Cooper Atem Zhitomir Neva Lux Arderia Nova
Thermona Immergas Electrolux Conord Lemax Galan Mora Aton

_______________________________________________________________________________

Do you want to equip your home with individual heating? Already installed and connected gas equipment? Great, then it remains to figure out how to turn on the gas boiler. Do you think it is enough to insert the plug into the socket and select the temperature? No matter how. Before this, it is necessary to bleed the air and fill the system with water. You will find instructions with a sequence of actions in our article.

The first start of the boiler: the beginning

The initial start allows you to assess the condition of the heating system.

Important! In the event of problems during independent switching on, the service center may refuse to guarantee. Perhaps the best solution would be to contact a specialist.

In any case, a specialist must carry out the connection to the gas pipeline. Installation and tying of equipment is carried out strictly according to the scheme. It is important to comply with the requirements for the room for a wall-mounted and floor-standing boiler, the distance from the wall and floor. If all installation work completed successfully, proceed to the next step.

Filling the system with water

In order for the liquid to enter the system, you need to open the water valve. It is located at the bottom of the case. More precisely, you can look in the instruction manual for your model "Ariston", "Proterm", "Navien" (Navien).

Unscrew the valve gradually, the water should not flow suddenly, otherwise an air lock will occur. As a result, problems with heating will begin. Keep an eye on the pressure gauge while filling. As soon as the values ​​\u200b\u200bare reached 2-2.5 atm, close the tap.

Work with water should be carried out in the warm season, otherwise the liquid will form plugs. If the temperature outside is below zero, warm the room up to 20 degrees.

After installing and filling a double-circuit or single-circuit heating boiler, take care of removing the remaining air in the pipes.

Bleeding air from the system

Automatically switched on equipment may have an air release function. But it is more efficient to do the work yourself. If you want the room to maintain a stable temperature, then eliminate the possibility of blockages in the pipeline. This is true for old and new models.

Start the process with radiators. Open the Mayevsky cranes located on them.

Pre-substitute containers, because water will drain with air. As soon as the whistling and hissing stops, you can close the taps.

Bleeding starts from the battery, which is located above the rest.

Before starting the boiler, bleed the air from the pump. Is it possible to do it yourself? It is better to carry out the first bleeding manually despite the automation. How to proceed:

  • Dismantle the case by unscrewing the screws;

  • Connect the Wisman, Kiturami, Aton boiler or the one you have at your disposal to the outlet;
  • As soon as the device is started, the pump will turn on and you will hear a gurgle;
  • Using a slotted screwdriver, unscrew the pump nut;

  • As soon as water flows, tighten the nut back. Repeat the process until the gurgling stops.

Keep track of the pressure gauge. If the pressure has dropped, add fluid to the circuit.

An important point is the setting of the batteries. The far radiators are turned on to the maximum, and the near ones to the minimum. As soon as a comfortable indicator is reached, proceed to the next step.

Contour pressing

During startup, this step is often ignored by users. But in vain! The procedure allows you to immediately find out how reliable and tight the system is. Judge for yourself: if a leak occurs at the height of the heating season and you are left without heat, the costs can be much greater. All you need is a pressure pump at hand.

Blow out the system with a powerful stream of air. The interval between switching on is 10 minutes. During this time, keep an eye on the manometer. Is the pressure starting to drop? So, there is a leak that needs to be found and fixed.

Wash cleansing

To ensure that nothing interferes with the circulation of water in the future, open all the taps on the radiators. Now supply liquid under a pressure of 4 bar, after substituting the containers. The flow will clean the pipes of rust and sediment. Then clean the filters from dirt.

How to turn on a gas boiler?

The system is ready, proceed to start the independent boiler. Is it possible to turn it on without gas? No, you need to follow the sequence.

For mounted units Bosch, Vaillant, Beretta, Ferroli (Ferroli), Protherm, Celtic and other models:

  • Plug the device into a socket;
  • Open the gas valve;
  • Press the "Start" button (depending on the model, there may be another key. See the instructions);
  • Using the buttons on the control panel "+" or "-" set the desired temperature;

  • The burner with electronic ignition will light up automatically when switching to hot water supply (DHW) or heating. For piezo ignition, hold down the flame control for a few seconds, then press the piezo button.

Important! During the initial start-up, air could accumulate inside the gas line, so the ignition may be blocked. To unlock, press the "Restart" key.

For parapet boilers of the Aton type, the inclusion is carried out in a similar way. If there remote control, then you can set the mode using the remote control.

How to properly turn on the outdoor units Buderus" (Buderus), "Baxi" (Baxi), "Lemax", " AOGV", "Conord", " Danko", " Siberia" and others:

  • Ventilate the room;
  • Make sure there is draft in the chimney;
  • Open the appliance door;

  • The control and temperature selector must be in the "Off" position;
  • Open the gas valve;
  • Set the selector to the piezo ignition position;
  • Press the selector for 5 seconds while pressing the piezo button. The burner should light up;
  • Use the same knob to adjust the temperature values.

Is it possible to leave the boiler on during absence? If you're away from home for an extended period of time, just set the rates to minimum. Low temperature and frost will lead to freezing of the entire system and other equipment. metal pipes can break under pressure, then you will have to completely change the heating circuit.

Double-circuit gas appliances make our life more comfortable and enjoyable. They are quite practical to use, suitable for heating country houses and small apartments. They are used for heating industrial or warehouse buildings, the area of ​​which is not more than 500 sq.m.

The advantages of Ariston boilers are that, in addition to heating buildings in winter period, they heat the water used in the home all year round. It is quite convenient and does not require the installation of additional equipment.

General characteristics of Ariston boilers

The description of Ariston gas units must begin with the characteristics of their main part - the burner. This element is used to burn fuel and to transfer thermal energy to the heating system.

Types of boiler burners:

  • ordinary
  • modulation

The modulating burner is more convenient to use. It provides for automatic power control depending on the temperature of the device.

According to the type of removal of combustion products, burners are divided into:

  • closed type
  • open type

Units with a closed type burner are safer to operate. The combustion products of natural gas in this case do not enter the room. Use is not required. A coaxial pipe is simply connected to the device and brought out.

Design coaxial pipe provides for the presence of two layers, which ensures the simultaneous removal of waste and the flow of air from the street into the burner.

Equipment with an open burner provides for the mandatory use of a chimney to remove combustion products.

Technical data of Ariston gas appliances

  • Ariston boilers are used for heating and heating water, that is, they are double-circuit. Each modification has its own characteristics, but the common type of fuel is gas.
  • The gas combustion chamber can be either open type or closed. In the presence of a chimney, units with an open chamber are used. And in apartments of multi-storey buildings, where there are not always chimneys, they use equipment with closed camera combustion.
  • Power. Using this indicator, the gas consumption required to heat the room is calculated.
  • Compactness. wall appliances used in small narrow rooms. Floor-standing units used in production or storage areas are heavier and require more space for installation.
  • The presence of a control unit. This element is indispensable when turning off the water, a sharp decrease in gas. In case of any malfunctions, the unit will immediately turn off the device, which will prevent damage. It can also save fuel consumption.
Ariston boilers are used for heating and water heating, that is, they are double-circuit

Characteristics of Ariston boiler models

A distinctive feature of Ariston boilers is their high quality. After all, the name of the company is translated from Greek as “the best”.

Its products are especially popular among middle-income consumers. gas boilers of this brand are purchased for space heating up to 500 sq.m. The company's products are universal. The transition to liquefied fuel is carried out only by replacing the burner.

Practical to use are dual-circuit wall-mounted gas appliances. It is represented by three lines, each with its own modifications.

For all modifications of boilers, the common is:

  • small size.
  • hot water supply, in the absence of its centralized supply.

Different modifications differ in structure, the common thing is their low cost and high-quality performance of parts.

Basic equipment of units from Ariston:

  • double .
  • electronic control module .
  • carbon monoxide control.
  • support of the microclimate in the building or in a separate apartment.
  • control of water freezing inside the system.

Let's take a closer look existing species Ariston equipment.


Ariston Genus

  • Are issued with the double heat exchanger. All modifications are double-circuit and are mounted on the wall.
  • This model is considered the most functional of all Ariston devices. It has an LCD display, a control panel with buttons. Ariston Genus can be configured to work offline for a whole week.
  • The display shows basic information about the status of the device and a list of possible errors. The burner is modulating, that is, fully controlled by electronics. This function increases the comfort of using this model of gas appliance, due to the minimum control by the consumer.

The Ariston Genus line includes Evo and more expensive Premium models.

The Evo model is a two-circuit gas appliance with a burner of both types: open and closed.

Genus Premium condensing boilers. They are used for heating residential buildings and commercial buildings. Power range from 24 kW to 35 kW.

Ariston Clas

  • Small size device.
  • This is a boiler with two circuits and a graceful appearance. The reduced dimensions did not impair its functionality in any way.
  • Expansion tank for 8 liters. Hot water is heated fairly quickly

Existing modification:

  • Evo is available in open and closed combustion chambers. Power with an open burner - 24 kW, with a closed - 24 - 28 kW.
  • Premium Evo condensing type appliance. Has advanced comfort and freezing functions
  • Premium simple condensing unit.

Ariston Egis

  • Installed mainly in rooms up to 200 sq.m.
  • The most common Ariston gas appliance model in our country. It heats water with a stainless steel heat exchanger, and a copper heat exchanger is used for heating.
  • The compact device, differs in profitability and can be used under complicated weather conditions. For example, at sharp sub-zero temperatures.
  • The device is equipped with a modulating gas burner , which allows for electronic control over the operation of the boiler.

This model is adapted to work in harsh climatic conditions. Normally withstands changes in gas pressure. The device is equipped with a collector into which condensate flows. This ensures operation at temperatures below 50 degrees.

The cost of boilers Ariston

The average cost of Ariston Genus boilers is 54,000 - 72,000 rubles, Ariston Clas - 25,000 - 34,000 rubles, Ariston Egis - 27,000 - 34,000 rubles

Choosing a gas appliance for heating

Ariston products can be found in the catalogs. There are many models of gas appliances. The main mistakes with the wrong choice of the unit are made from a lack of information. Therefore, before visiting the store, you should familiarize yourself with the basic tips for choosing a wall-mounted gas appliance.

When choosing a boiler, consider the following points:

  • The size of the kitchen, as the place where the heating device is most often installed. In the store, the choice begins with consideration overall dimensions apparatus and select it individually for your kitchen.
  • Then they go to the technical data and study the type of water heater in the device. If in a family a large number of person, it is not recommended to purchase a boiler with.
  • In this case, it is more rational to purchase a boiler with storage tank for hot water and choose equipment for the amount of water that you will need for everyday use.
  • Evaluate the combustion chamber of gas equipment. It is closed and open. It is recommended to choose a boiler with a closed chamber, because it is safer to operate. The presence of a chimney is optional, which is important in multi-storey buildings. It is enough to buy and bring a coaxial pipe to the street.

As a rule, we entrust the first start-up of a gas boiler and work on setting up and adjusting it to masters from service centers. Why? Yes, because without their mark in the equipment passport, the manufacturer's warranty is simply not valid, and in the event of an early breakdown, we will simply be denied warranty repairs.

Whether this is actually the case is, of course, debatable. Specialists from service center will find a million reasons to refuse you free equipment repair. And even if you get such generosity from them, then your repair will last more than one week - then there are no spare parts, then the queue has not yet come, then it’s wrong. This is a proven fact and it is very difficult to disprove it. If you want a quick "warranty repair" - pay both for spare parts and for the work of the master.

By the way, to put the boiler on warranty service also need to pay money. So what is this guarantee? Pay for the warranty, then pay for parts and repairs. So where is the free warranty service? That is why, since you already have to pay for everything, I suggest that you independently start the gas boiler for the first time and set up the heating system. Moreover, it is not difficult.

Filling the heating system with water

We look under the bottom of the boiler - where all the pipelines are connected, and look for something like a small valve there. For each model of a gas boiler, it can have a different shape: one manufacturer makes it in the form of a valve familiar to us, the other in the form of a rotating plastic pin. In general, from their form, the essence does not change - in extreme cases, open the instructions and look at its location.

We open this tap, not completely (so that air does not hang anywhere in the pipes, it is better to fill the system slowly) and fix our eyes on the pressure indicator - the pressure gauge. As a rule, most boilers of this type have an operating pressure of 1 to 3 atm - read the instructions for more details. We wait until the pressure gauge needle reaches 2.5 atm, close the valve.

Now the boiler will have to be left alone for a while - from each installed battery or convector must be vented.

For these purposes, each heater must be equipped with a Mayevsky crane. We open it and wait for the air to come down and the water to run. The water went - they closed the Mayevsky tap. This procedure must be done with each battery. Have you done?

Now we return to the boiler and again look at the pressure gauge - the pressure in the system should drop. We correct it, add water if necessary - the optimal pressure at which the boiler works normally is 1.5-2 atm. If you pump more, then during operation at a high temperature of the coolant, excess pressure will be released. This is due to the fact that when the liquid is heated, its pressure increases.

First start of the gas boiler

Having done all these simple preparations, you can proceed to the direct start of the boiler. Open the gas valve and plug the boiler into the socket. All sorts of symbols and numbers appear on the screen, but for a full launch, you still need to perform some actions.

First, press the power button and set the temperature control knobs to the operating position. After these actions, the boiler will begin to make futile attempts to turn on - this is normal and there is no need to be scared. The most important thing is that the circulation pump has started to work, inside which for some reason there is always air that prevents the boiler from fully turning on. It is his removal that needs to be done as soon as possible.


We remove the front cover of the boiler - in almost all cases it is fastened with two or four screws. We fold back the dashboard, behind which the circulation pump hides.

In the center of the pump there is a wide screw with a slot for a screwdriver. Here it is, dear, and you need to unscrew it a little, and when water runs out from under it without air bubbles, twist it again. Only now will the full circulation of the liquid in the heating system begin, and the boiler will start working.

At first, he will gurgle, make some strange sounds, but this is only for the better. Just be aware that all these sounds indicate that the air remaining in the system is being expelled into expansion tank, where automatic air valve releases it outside. Five minutes will pass and the system will return to normal - the pressure will stabilize, and the gurgling sounds will subside. And five minutes later you will already be enjoying warmer batteries and unlimited hot water in the faucet.

Here, in principle, is everything you need to know in order to carry out the first start-up of a gas boiler. The boiler is working, the batteries are getting warmer, and I think you will figure it out for yourself how to regulate the temperature of the batteries and hot water in the tap - read the instructions, everything is intelligibly described there regarding the control of your particular boiler model.

Was this article helpful to you? Subscribe to site updates to receive the latest articles on renovation and interior design before anyone else!

The last stage of installation of almost any heating system is its first trial run, debugging and commissioning. By by and large, if boiler equipment is launched for the first time, then this work is a priority for service centers. During the first start-up, the specialists of the service center check the correct connection of the boiler, debug it and put this equipment under warranty. If you carry out the first launch yourself, then you can not count on the warranty service center. Starting and debugging the heating system can also be carried out during the operation of the system - you will not turn to specialists every time. Owners of individual heating just need to know this process. We will study it with you in this master class with step by step photos, in which, together with the site, we will study in detail the issues of how the boiler is started up and how the heating system is debugged with our own hands.

Filling the heating system with water

Starting a gas boiler begins with filling the heating system with water. Everything is simple here - modern double-circuit boilers do not require the device of a special unit for feeding the system. It is already built into the boiler and is equipped with a special faucet, which, as a rule, is located at the bottom of the boiler in close proximity to the connection pipe. cold water. Open the make-up tap and slowly fill the system with water.

Starting the boiler - how to fill the system with water

Highly important point in the operation of any boiler equipment is the fluid pressure. To control this parameter of the heating system, almost all boilers are equipped with a pressure gauge. In the process of filling the systems with water, it is necessary to monitor the pressure and after it reaches 1.5-2 atm, the filling of the system will need to be stopped. In principle, the indicator of the working pressure of the boiler, depending on the manufacturer and model, may vary - therefore, see the exact figure for the working pressure in the instructions for the boiler.

Do-it-yourself first start-up of a gas boiler

Removal of air locks in the system

Better to start with batteries. To remove air jams, a Mayevsky crane is usually installed on them. We open it and wait for the water to run. Did you run? We close. Such manipulations must be done with each heating device separately.

How to start the boiler with your own hands photo

After the air is removed from the batteries, the pressure in the system will decrease and the pressure gauge needle will drop. On the this stage work, the solution to the question of how to start the boiler involves re-feeding the system with liquid.

Now, the most difficult thing is that starting gas boilers requires venting air from the circulation pump. To do this, the boiler needs to be disassembled a little. Remove the front cover and look for an object cylindrical shape with a shiny cap in the middle, with a slot for a screwdriver. After we have found it, we put the boiler into operation - we supply it with electric power and set the water heating regulators to the working position.

Releasing air from the circulation pump when starting the boiler photo

The circulation pump will immediately turn on - you will hear a faint hum and a loud gurgling and many incomprehensible sounds. This is fine. As long as the pump is airy, it will be so. We take a screwdriver and slowly unscrew the cover in the middle of the pump - as soon as water begins to seep out from under it, we twist it back. After two or three such manipulations, the air will come out completely, incomprehensible sounds will subside, the electric ignition will work and start working. We check the pressure again and, if necessary, add water to the system.

Basically, everything. While the system is warming up, you can do a detailed study of the instructions (if, of course, you have not already done so) and debug the system, which involves starting the boiler. Everything is simple here - the batteries closest to the boiler must be screwed on, and the distant ones should be run to the fullest. Such debugging is carried out by means of control valves installed on the pipe connecting the supply to the heating radiator.