Evaporators, evaporative units, evaporative-mixing units, block autonomous PP-TEC complexes. But our problems, oddly enough, do not end there.

The use of "green" energy supplied by natural elements can significantly reduce utility costs. For example, by arranging solar heating of a private house, you will supply virtually free heat carrier low temperature radiators and underfloor heating systems. Agree, this is already saving.

You will learn everything about “green technologies” from our article. With our help, you can easily understand the types of solar installations, how they are constructed and the specifics of operation. Surely you will be interested in one of the popular options that are intensively working in the world, but not yet very popular with us.

In the review presented to your attention, the design features of the systems are disassembled, the connection diagrams are described in detail. An example of the calculation of a solar heating circuit to assess the realities of its construction is given. Photo collections and videos are attached to help independent masters.

On average, 1 m 2 of the earth's surface receives 161 W solar energy at one o'clock. Of course, at the equator this figure will be many times higher than in the Arctic. In addition, the density of solar radiation depends on the time of year.

In the Moscow region, the intensity of solar radiation in December-January differs from May-July by more than five times. However modern systems so efficient that they can work almost anywhere on earth.

MEL Group of Companies is a wholesale supplier of Mitsubishi Heavy Industries air conditioning systems.

www.site This email address is being protected from spambots. You must have JavaScript enabled to view.

Compressor-condensing units (CCU) for cooling ventilation are becoming more common in the design of central cooling systems for buildings. Their advantages are obvious:

Firstly, this is the price of one kW of cold. Compared to chiller systems, supply air cooling with KKB does not contain an intermediate coolant, i.e. water or antifreeze solutions, so it is cheaper.

Secondly, the convenience of regulation. One compressor and condenser unit works for one air handling unit, so the control logic is the same and is implemented using standard air handling unit control controllers.

Thirdly, the ease of installation of KKB for cooling the ventilation system. No additional air ducts, fans, etc. are needed. Only the evaporator heat exchanger is built in and that's it. Even additional insulation of supply air ducts is often not required.

Rice. 1. KKB LENNOX and the scheme of its connection to the supply unit.

Against the background of such remarkable advantages, in practice we are faced with many examples of air conditioning ventilation systems in which KKB either do not work at all, or fail very quickly during operation. An analysis of these facts shows that often the reason is the wrong selection of the KKB and the evaporator for cooling the supply air. Therefore, we will consider the standard method for selecting compressor and condenser units and try to show the errors that are made in this case.

INCORRECT, but the most common, method for selecting a KKB and an evaporator for direct-flow air handling units

  1. As initial data, we need to know the air flow air handling unit. Let's set for example 4500 m3/hour.
  2. Supply unit direct-flow, i.e. no recirculation, runs on 100% outside air.
  3. Let's define the area of ​​construction - for example, Moscow. Estimated parameters of outdoor air for Moscow + 28C and 45% humidity. These parameters are taken as the initial parameters of the air at the inlet to the evaporator of the supply system. Sometimes the air parameters are taken "with a margin" and set + 30C or even + 32C.
  4. Let us set the required air parameters at the outlet of the supply system, i.e. at the entrance to the room. Often these parameters are set 5-10C lower than the required supply air temperature in the room. For example, + 15C or even + 10C. We will focus on the average value of +13C.
  5. Coming from i-d diagrams (Fig. 2) we build the process of air cooling in the ventilation cooling system. Determine the amount of cold needed given conditions. In our version, the required cooling consumption is 33.4 kW.
  6. We select KKB according to the required cold consumption of 33.4 kW. There is the nearest large and the nearest smaller model in the KKB line. For example, for the manufacturer LENNOX, these are the models: TSA090 / 380-3 for 28 kW of cold and TSA120 / 380-3 for 35.3 kW of cold.

We accept a model with a margin of 35.3 kW, i.e. TSA120/380-3.

And now we will tell you what will happen at the facility, with the joint operation of the air handling unit and the KKB selected by us according to the method described above.

The first problem is the overestimated performance of the KKB.

The ventilation air conditioner is selected for the parameters of the outside air + 28C and 45% humidity. But the customer plans to operate it not only when it is +28C outside, it is often already hot in the rooms due to internal heat surpluses starting from +15C outside. Therefore, the controller sets the supply air temperature at best +20C, and at worst even lower. The KKB gives either 100% capacity or 0% (with rare exceptions of smooth regulation when using outdoor VRF units in the form of KKB). KKB does not reduce its performance when the temperature of the outside (intake) air decreases (in fact, it even slightly increases due to greater subcooling in the condenser). Therefore, when the air temperature at the evaporator inlet decreases, the KKB will tend to produce a lower air temperature at the evaporator outlet. With our calculation data, the outlet air temperature is +3C. But this cannot be, because the boiling point of freon in the evaporator is +5C.

Consequently, lowering the air temperature at the inlet to the evaporator to +22C and below, in our case, leads to an overestimated performance of the KKB. Further, the freon does not boil in the evaporator, the liquid refrigerant returns to the compressor suction and, as a result, the compressor fails due to mechanical damage.

But our problems, oddly enough, do not end there.

The second problem is the LOWER EVAPORATOR.

Let's take a closer look at the selection of an evaporator. When selecting a supply unit, specific parameters of the evaporator operation are set. In our case, this is the air temperature at the inlet + 28C and humidity 45% and at the outlet + 13C. Means? the evaporator is selected EXACTLY on these parameters. But what will happen when the air temperature at the evaporator inlet is, for example, not +28C, but +25C? The answer is quite simple if you look at the heat transfer formula of any surfaces: Q=k*F*(Tv-Tf). k*F - heat transfer coefficient and heat exchange area will not change, these values ​​are constant. Tf - the boiling point of freon will not change, because it is also maintained at a constant +5C (during normal operation). But Tv - the average air temperature has decreased by three degrees. Consequently, the amount of heat transferred will also decrease in proportion to the temperature difference. But KKB "does not know about it" and continues to give the required 100% performance. Liquid freon returns to the compressor suction again and leads to the problems described above. Those. design evaporator temperature is MINIMUM operating temperature KKB.

Here you can object - "But what about the work of on-off split systems?" the calculated temperature in the splits is +27C in the room, but in fact they can work up to +18C. The fact is that in split systems, the surface area of ​​the evaporator is selected with a very large margin, at least 30%, just to compensate for the decrease in heat transfer when the temperature in the room drops or the fan speed of the indoor unit decreases. And finally,

The third problem is the selection of KKB "With a reserve" ...

The performance margin in the selection of KKB is extremely harmful, because. the reserve is liquid freon at the compressor suction. And in the final we have a jammed compressor. In general, the maximum evaporator capacity should always be greater than the compressor capacity.

We will try to answer the question - how is it CORRECT to select a KKB for supply systems?

First, it is necessary to understand that the source of cold in the form of a condensing unit cannot be the only one in the building. Conditioning the ventilation system can only remove part of the peak load entering the room with ventilation air. And maintaining a certain temperature inside the room in any case falls on local closers ( indoor units VRF or fan coil units). Therefore, the KKB should not maintain a certain temperature when cooling the ventilation (this is impossible due to on-off regulation), but reduce the heat input to the premises when a certain outside temperature is exceeded.

An example of a ventilation system with air conditioning:

Initial data: the city of Moscow with design parameters for air conditioning + 28C and 45% humidity. Supply air consumption 4500 m3/hour. Heat surpluses of the room from computers, people, solar radiation, etc. are 50 kW. Estimated room temperature +22C.

The air conditioning capacity must be selected in such a way that it is sufficient under the worst conditions (maximum temperatures). But also ventilation air conditioners should work without problems even with some intermediate options. Moreover, most of the time, ventilation air conditioning systems operate just at a load of 60-80%.

  • Set the calculated outdoor temperature and the calculated indoor temperature. Those. The main task of the KKB is to cool the supply air to the room temperature. When the outdoor air temperature is less than the required indoor air temperature, the KKB DOES NOT turn ON. For Moscow, from +28C to the required room temperature of +22C, we get a temperature difference of 6C. In principle, the temperature difference across the evaporator should not exceed 10°C, since the supply air temperature cannot be less than the boiling point of freon.
  • We determine the required performance of the KKB based on the conditions for cooling the supply air from the design temperature of +28C to +22C. It turned out 13.3 kW of cold (i-d diagram).

  • According to the required performance, we select 13.3 KKB from the line of the popular manufacturer LENNOX. We select the nearest SMALLER KKB TSA036/380-3s with a productivity of 12.2 kW.
  • We select the supply evaporator from the worst parameters for it. This is the outdoor temperature equal to the required indoor temperature - in our case + 22C. The cold performance of the evaporator is equal to the performance of the KKB, i.e. 12.2 kW. Plus a performance margin of 10-20% in case of evaporator contamination, etc.
  • We determine the temperature of the supply air at an outdoor temperature of + 22C. we get 15C. Above the boiling point of freon + 5C and above the dew point temperature + 10C, then the insulation of the supply air ducts can be omitted (theoretically).
  • We determine the remaining heat surpluses of the premises. It turns out 50 kW of internal heat surpluses plus a small part of the supply air 13.3-12.2 = 1.1 kW. Total 51.1 kW - design capacity for local control systems.

Findings: the main idea that I would like to draw attention to is the need to calculate the compressor capacitor unit not on maximum temperature outside air, and to the minimum in the operating range of the ventilation air conditioner. The calculation of the KKB and the evaporator, carried out for the maximum temperature of the supply air, leads to the fact that normal operation will only be in the range of outdoor temperatures from the calculated one and above. And if the outside temperature is lower than the calculated one, there will be incomplete boiling of freon in the evaporator and return of the liquid refrigerant to the compressor suction.

In the case when the consumption of the vapor phase liquefied gas exceeds the rate of natural evaporation in the tank, it is necessary to use evaporators, which, due to electrical heating, accelerate the process of vaporization of the liquid phase into steam and guarantee the gas supply to the consumer in the calculated volume.

The purpose of the LPG evaporator is the conversion of the liquid phase of liquefied hydrocarbon gases (LHG) into a vapor phase, which occurs through the use of electrically heated evaporators. Evaporation units can be equipped with one, two, three or more electric evaporators.

Installation of evaporators allows the operation of both one evaporator and several in parallel. Thus, the capacity of the plant may vary depending on the number of simultaneously operating evaporators.

The principle of operation of the evaporation plant:

When the evaporator is turned on, the automation heats the evaporator to 55C. The solenoid valve at the liquid phase inlet to the evaporator will be closed until the temperature reaches these parameters. The level control sensor in the cut-off (if there is a level gauge in the cut-off) controls the level and, in case of overflow, closes the valve at the inlet.

The evaporator starts to heat up. When 55°C is reached, the inlet solenoid valve will open. The liquefied gas enters the heated pipe register and evaporates. During this time, the evaporator continues to heat up, and when the core temperature reaches 70-75°C, the heating coil will be turned off.

The evaporation process continues. The evaporator core gradually cools down, and when the temperature drops to 65°C, the heating coil will be switched on again. The cycle is repeated.

Complete set of evaporative plant:

The evaporation plant can be equipped with one or two control groups to duplicate the reduction system, as well as the bypass line of the vapor phase, bypassing the evaporation plant to use the vapor phase of natural evaporation in gas holders.

Pressure regulators are used to set a predetermined pressure at the outlet of the evaporation plant to the consumer.

  • 1st stage - medium pressure adjustment (from 16 to 1.5 bar).
  • 2nd stage - adjustment low pressure from 1.5 bar to the pressure required when supplying to the consumer (for example, to a gas boiler or a gas piston power plant).

Advantages of PP-TEC evaporation plants "Innovative Fluessiggas Technik" (Germany)

1. Compact structure, light weight;
2. Profitability and safety of operation;
3. Large thermal power;
4. Long service life;
5. Stable performance under low temperatures;
6. Duplicated system for monitoring the exit of the liquid phase from the evaporator (mechanical and electronic);
7. Antifreeze protection of filter and solenoid valve (PP-TEC only)

Package Included:

Double gas temperature control thermostat,
- liquid level sensors,
- solenoid valves at the liquid phase inlet
- a set of safety fittings,
- thermometers,
- ball valves for emptying and deaeration,
- built-in gas liquid phase cutter,
- input / output fittings,
- terminal boxes for power supply connection,
- electrical control panel.

Advantages of PP-TEC evaporators

When designing an evaporative plant, there are always three things to consider:

1. Ensure the specified performance,
2. Create the necessary protection against hypothermia and overheating of the evaporator core.
3. Correctly calculate the geometry of the location of the coolant to the gas conductor in the evaporator

The performance of the evaporator depends not only on the amount of voltage consumed from the mains. An important factor is the location geometry.

Proper placement provides effective use heat transfer mirrors and, as a result, an increase in the efficiency of the evaporator.

In evaporators "PP-TEC "Innovative Fluessiggas Technik" (Germany), by correct calculations, the company's engineers have achieved an increase in this coefficient up to 98%.

Evaporative plants of the company “PP-TEC “Innovative Fluessiggas Technik” (Germany) lose only two percent of heat. The rest is used to vaporize the gas.

Almost all European and American manufacturers of evaporative equipment completely erroneously interpret the concept of "redundant protection" (a condition for the implementation of duplication of the functions of protection against overheating and hypothermia).

The concept of "redundant protection" implies the implementation of the "safety net" of individual working units and blocks or the entire equipment, by using duplicated elements from different manufacturers and with different principles of operation. Only in this case it is possible to minimize the possibility of equipment failure.

Many manufacturers are trying to implement this function (with protection against hypothermia and ingress of the LPG liquid fraction to the consumer) by installing two solenoid valves connected in series from the same manufacturer on the inlet supply line. Or use two temperature sensors connected in series to turn on / open the valves.

Imagine the situation. One solenoid valve stuck open. How can you tell if a valve has failed? NO WAY! The unit will continue to work, losing the opportunity to ensure the safety of operation in case of hypothermia in time in case of failure of the second valve.

In PP-TEC evaporators, this function has been implemented in a completely different way.

In evaporation plants, the company “PP-TEC “Innovative Fluessiggas Technik” (Germany) uses the algorithm of cumulative work three elements hypothermia protection:

1. Electronic device
2. Magnetic valve
3. Mechanical shut-off valve in the slam-shut.

All three elements have a completely different principle of operation, which makes it possible to speak with confidence about the impossibility of a situation in which non-evaporated gas in liquid form enters the consumer's pipeline.

In the evaporative units of the company “PP-TEC “Innovative Fluessiggas Technik” (Germany), the same thing was implemented when implementing the protection of the evaporator from overheating. The elements involve both electronics and mechanics.

PP-TEC "Innovative Fluessiggas Technik" (Germany) for the first time in the world implemented the function of integrating a liquid cutter into the cavity of the evaporator itself with the possibility of constant heating of the cutter.

No manufacturer of evaporative technology uses this proprietary function. Using a heated cut-off device, PP-TEC “Innovative Fluessiggas Technik” (Germany) evaporative units were able to evaporate the heavy components of LPG.

Many manufacturers, copying from each other, install a cut-off at the outlet in front of the regulators. The mercaptans, sulfurs and heavy gases contained in the gas, which have a very high density, get into the cold pipeline, condense and deposit on the walls of the pipes, cut-off and regulators, which significantly reduces the service life of the equipment.

In the evaporators of PP-TEC "Innovative Fluessiggas Technik" (Germany), heavy precipitates in the molten state are kept in the cutter until they are removed through the discharge ball valve in the evaporator plant.

By cutting off mercaptans, PP-TEC "Innovative Fluessiggas Technik" (Germany) was able to significantly increase the service life of plants and regulatory groups. This means taking care of operating costs that do not require constant replacement of regulator membranes, or their complete and expensive replacement, leading to downtime of the evaporation plant.

And the implemented function of heating the solenoid valve and the filter at the inlet to the evaporator plant does not allow water to accumulate in them and, when frozen in the solenoid valves, to disable when triggered. Or limit the entry of the liquid phase into the evaporation plant.

Evaporation plants German company“PP-TEC “Innovative Fluessiggas Technik” (Germany) is a reliable and stable operation for many years of operation.

Evaporators

In the evaporator, the liquid refrigerant boils and turns into a vapor state, removing heat from the cooled medium.

Evaporators are divided into:

by type of cooled medium - for cooling gaseous media (air or other gas mixtures), for cooling liquid heat carriers (coolants), for cooling solid bodies (products, technological substances), evaporators-condensers (in cascade refrigeration machines Oh);

depending on the conditions of movement of the cooled media - with natural circulation of the cooled medium, with forced circulation of the cooled medium, for cooling stationary media (contact cooling or freezing of products);

according to the method of filling - flooded and non-flooded types;

according to the method of organizing the movement of the refrigerant in the apparatus - with natural circulation of the refrigerant (circulation of the refrigerant under the action of a pressure difference); with forced coolant circulation (with circulation pump);

depending on the method of organizing the circulation of the cooled liquid - with a closed system of the cooled liquid (shell-and-tube, shell-and-coil), with open system cooled liquid (panel).

Most often, the medium for cooling is air - a universal coolant that is always available. Evaporators differ in the type of channels in which the refrigerant flows and boils, the profile of the heat exchange surface and the organization of air movement.

Types of evaporators

Sheet-tube evaporators are used in household refrigerators. Made from two sheets with stamped channels. After the channels are aligned, the sheets are joined by roller welding. The assembled evaporator can be given the appearance of a U- or O-shaped structure (in the form of a low-temperature chamber). The heat transfer coefficient of sheet-tube evaporators is from 4 to 8 V / (m-square * K) at a temperature difference of 10 K.

a, b - O-shaped; c - panel (shelf-evaporator)

Smooth-tube evaporators are coils of pipes that are attached to the racks with brackets or soldering. For ease of installation, smooth-tube evaporators are made in the form of wall-mounted batteries. A battery of this type (wall-mounted smooth-tube evaporative batteries of the BN and BNI types) is used on ships to equip food storage chambers. To cool the provisional chambers, smooth-tube wall-mounted batteries designed by VNIIkholodmash (ON26-03) are used.

Finned-tube evaporators are most widely used in commercial refrigeration equipment. Evaporators are made of copper pipes with a diameter of 12, 16, 18 and 20 mm with a wall thickness of 1 mm or brass tape L62-T-0.4 with a thickness of 0.4 mm. To protect the surface of pipes from contact corrosion, they are coated with a layer of zinc or chrome plated.

To equip refrigerating machines with a capacity of 3.5 to 10.5 kW, IRSN evaporators are used (dry wall-mounted finned-tube evaporator). Evaporators are made from copper pipe with a diameter of 18 x 1 mm, finning - from a brass tape 0.4 mm thick with a rib pitch of 12.5 mm.

A finned-tube evaporator equipped with a fan for forced air circulation is called an air cooler. The heat transfer coefficient of such a heat exchanger is higher than that of a finned evaporator, and therefore the dimensions and weight of the apparatus are smaller.

evaporator malfunction technical heat transfer


Shell and tube evaporators are evaporators with closed circulation of the cooled liquid (heat transfer medium or liquid process medium). The liquid to be cooled flows through the evaporator under pressure generated by the circulation pump.

In shell-and-tube flooded evaporators, the refrigerant boils on the outer surface of the tubes, and the liquid to be cooled flows inside the tubes. closed system circulation allows you to reduce the cooling system due to reduced contact with air.

To cool water, shell-and-tube evaporators are often used with the refrigerant boiling inside the tubes. The heat exchange surface is made in the form of pipes with internal fins and the refrigerant boils inside the pipes, and the cooled liquid flows in the annulus.

Operation of evaporators


· When operating evaporators, it is necessary to comply with the requirements of the manufacturer's instructions, these Rules and production instructions.

· When the pressure on the discharge lines of the evaporators is higher than that provided for by the project, the electric motors and heat carriers of the evaporators should automatically turn off.

Evaporators are not allowed to operate with faulty or switched off ventilation, with faulty instrumentation or their absence, if there is a gas concentration in the room that exceeds 20% of the lower concentration limit flame spread.

· Information about the mode of operation, the amount of time worked by compressors, pumps and evaporators, as well as malfunctions in operation, should be reflected in the operating log.

· Conclusion of evaporators from the operating mode to the reserve should be carried out in accordance with the production instructions.

After switching off the evaporator shut-off valves on the suction and discharge lines must be closed.

The air temperature in the evaporator compartments in work time must be at least 10 °C. When the air temperature is below 10 °C, it is necessary to drain the water from the water supply, as well as from the cooling system of the compressors and the heating system of the evaporators.

· Evaporation compartments should have technological schemes of equipment, pipelines and instrumentation, operating instructions for installations and operating logs.

· Maintenance evaporators is carried out by operating personnel under the guidance of a specialist.

· Maintenance evaporative equipment includes maintenance and inspection operations, partial disassembly of equipment with repair and replacement of wearing parts and parts.

During the operation of evaporators, the requirements for safe operation pressure vessels.

· Maintenance and repair of evaporators must be carried out in the scope and terms specified in the manufacturer's passport. Maintenance and repair of gas pipelines, fittings, automatic safety devices and instrumentation of evaporators must be carried out within the time limits established for this equipment.

Operation of evaporators is not allowed in the following cases:

1) increasing or decreasing the pressure of the liquid and vapor phases above or below the established norms ;

2) malfunctions safety valves, instrumentation and automation equipment;

3) failure to verify instrumentation;

4) failure of fasteners;

5) detection of gas leakage or sweating in welds, bolted joints, as well as violations of the integrity of the evaporator structure;

6) ingress of the liquid phase into the gas pipeline of the vapor phase;

7) stopping the supply of coolant to the evaporator.

Evaporator repair

Too weak evaporator . Generalization of symptoms

In this section, we will define the "evaporator too weak" fault as any fault that leads to an abnormal reduction in cooling capacity due to the fault of the evaporator itself.

Diagnosis algorithm


The "evaporator too weak" fault, and the resulting abnormal evaporation pressure drop, is the most easily detected as this is the only fault in which a normal or slightly reduced superheat occurs simultaneously with an abnormal evaporation pressure drop.

Practical aspects

Dirty pipes and heat exchange fins of the evaporator

The danger of this defect occurs mainly in plants that are poorly maintained. A typical example of such an installation is an air conditioner that does not have an air filter at the evaporator inlet.

When cleaning the evaporator, it is sometimes enough to blow the fins with a jet compressed air or nitrogen in the opposite direction to the air movement during operation of the unit, but in order to completely cope with the dirt, it is often necessary to use special cleaning and detergents. In some particularly severe cases, it may even be necessary to replace the evaporator.

Dirty air filter

In air conditioners, fouling of the air filters installed at the evaporator inlet leads to an increase in airflow resistance and, as a result, a drop in air flow through the evaporator, which causes an increase in temperature difference. Then the repairman must clean or change the air filters (for filters of similar quality), not forgetting to ensure free access to outside air when installing new filters.

It seems useful to recall that the air filters must be in perfect condition. Especially at the outlet facing the evaporator. The filter material must not be allowed to be torn or lose thickness during repeated washes.

If the air filter is in poor condition or not suitable for the evaporator, dust particles will not be captured well and will cause fouling of the evaporator tubes and fins over time.

Evaporator fan belt slipping or broken

If the fan belt(s) slip, the fan speed drops, resulting in a reduction in air flow through the evaporator and an increase in air temperature differential (at the limit, if the belt is broken, there is no air flow at all).

Before tightening the belt, the repairman should check for wear and replace if necessary. Of course, the repairer should also check the alignment of the belts and thoroughly inspect the drive (cleanliness, mechanical clearances, grease, tension), as well as the condition of the drive motor with the same care as the fan itself. Each repairman, of course, cannot have all existing models of drive belts in stock in his car, so you first need to check with the client and select the right kit.

Poorly adjusted pulley with variable chute width

Most modern air conditioners are equipped with fan drive motors, on the axis of which a pulley of variable diameter (variable chute width) is installed.

At the end of the adjustment, it is necessary to fix the movable cheek on the threaded part of the hub using a locking screw, while the screw should be tightened as tightly as possible, carefully making sure that the screw leg rests against a special flat on the threaded part of the hub and prevents damage to the thread. Otherwise, if the thread is crushed by the locking screw, further adjustment of the depth of the gutter will be difficult, and may even be impossible. After adjusting the pulley, in any case, check the current consumed by the electric motor (see description of the following fault).

High pressure loss in the evaporator air path

If a the variable diameter pulley is adjusted to the maximum fan speed and the air flow is still insufficient, which means that the losses in the air path are too high in relation to the maximum fan speed.

After you have made sure that there are no other problems (a damper or valve is closed, for example), it should be considered advisable to replace the pulley in such a way as to increase the fan speed. Unfortunately, increasing the speed of the fan requires not only the replacement of the pulley, but also entails other consequences.

The evaporator fan rotates in the opposite direction

The risk of such a malfunction always exists during commissioning. new installation when the evaporator fan is equipped with a three-phase drive motor (in this case, it is sufficient to swap two phases to restore the correct direction of rotation).

The fan motor, being powered by a 60 Hz mains supply, is connected to a 50 Hz mains supply

This problem, fortunately quite rare, can mainly affect motors made in the USA and intended for connection to a 60 Hz AC mains. Note that some motors made in Europe and intended for export may also require a supply frequency of 60 Hz. You can quickly understand the cause of this malfunction very simply enough for the repairman to read specifications motor on a special plate attached to it.

3 pollution a large number evaporator fins

If many evaporator fins are covered with dirt, the resistance to air movement through it increased, which leads to a decrease in air flow through the evaporator and an increase in air temperature drop.

And then the repairman will have no choice but to thoroughly clean the contaminated parts of the evaporator fins on both sides with a special comb with a tooth pitch that exactly matches the distance between the fins.

Evaporator Maintenance

It consists in providing heat removal from the heat transfer surface. For this purpose, the supply of liquid refrigerant to the evaporators and air coolers is regulated to create the required level in flooded systems or in the amount necessary to ensure optimal superheating of the exhaust steam in non-flooded ones.

The safety of operation of evaporative systems largely depends on the regulation of the refrigerant supply and the order in which the evaporators are turned on and off. The refrigerant supply is regulated in such a way as to prevent vapor breakthrough from the side high pressure. This is achieved by smooth control operations, maintaining the required level in the linear receiver. When connecting disconnected evaporators to a running system, it is necessary to prevent the wet running of the compressor, which can occur due to the release of steam from the heated evaporator along with drops of liquid refrigerant during its sudden boiling after careless or ill-conceived opening of the shut-off valves.

The connection order of the evaporator, regardless of the duration of the shutdown, must always be as follows. Stop the supply of refrigerant to the running evaporator. Close the suction valve on the compressor and gradually open the shut-off valve on the evaporator. After that, the compressor suction valve is also gradually opened. Then regulate the flow of refrigerant to the evaporators.

To ensure an efficient heat transfer process in the evaporators of refrigeration units with brine systems, ensure that the entire heat transfer surface is immersed in the brine. In open type evaporators, the brine level should be 100-150 mm above the evaporator section. During the operation of shell-and-tube evaporators, the timely release of air through the air valves is monitored.

When servicing evaporative systems, they monitor the timeliness of thawing (thawing) of the frost layer on batteries and air coolers, check whether the melt water drainage pipeline is frozen, monitor the operation of fans, the density of closing hatches and doors to avoid loss of cooled air.

During defrosting, they monitor the uniformity of the supply of heating vapors, avoiding uneven heating of individual parts of the apparatus and not exceeding the heating rate of 30 CCH.

The supply of liquid refrigerant to air coolers in pumpless installations is controlled by the level in the air cooler.

In installations with a pump circuit, the uniformity of the refrigerant flow to all air coolers is regulated depending on the freezing rate.

Bibliography

Installation, operation and repair refrigeration equipment. Textbook (Ignatiev V.G., Samoilov A.I.)

One of the most important elements for a vapor compression machine is. It performs the main process of the refrigeration cycle - selection from the cooled medium. Other elements refrigeration circuit, such as a capacitor, expansion device, compressor, etc., only ensure the reliable operation of the evaporator, so it is the choice of the latter that must be given due attention.

It follows from this that, when selecting equipment for a refrigeration unit, it is necessary to start with the evaporator. Many novice repairmen often admit typical mistake and start the assembly of the installation with the compressor.

On fig. 1 shows a diagram of the most common vapor compression refrigeration machine. Its cycle, given in coordinates: pressure R and i. On fig. 1b points 1-7 of the refrigeration cycle, is an indicator of the state of the refrigerant (pressure, temperature, specific volume) and coincides with that in Fig. 1a (state parameter functions).

Rice. 1 - Scheme and in the coordinates of a conventional vapor compression machine: RU expansion device, Рk- condensation pressure, Ro- boiling pressure.

Graphic image fig. 1b displays the state and functions of the refrigerant, which vary with pressure and enthalpy. Line segment AB on the curve in Fig. 1b characterizes the refrigerant in the state of saturated vapor. Its temperature corresponds to the initial boiling point. The proportion of refrigerant vapor in is 100% and the superheat is close to zero. To the right of the curve AB the refrigerant has a state (the temperature of the refrigerant is greater than the boiling point).

Dot AT is critical for this refrigerant, since it corresponds to the temperature at which the substance cannot go into a liquid state, no matter how high the pressure is. On segment BC, the refrigerant has a state of saturated liquid, and on the left side it has a state of supercooled liquid (the temperature of the refrigerant is less than the boiling point).

Inside the curve ABC the refrigerant is in the state of a vapor-liquid mixture (the proportion of vapor per unit volume is variable). The process occurring in the evaporator (Fig. 1b) corresponds to the segment 6-1 . The refrigerant enters the evaporator (point 6) in the state of a boiling vapor-liquid mixture. In this case, the proportion of steam depends on a specific refrigeration cycle and is 10-30%.

At the outlet of the evaporator, the boiling process may not be completed and the point 1 may not match the dot 7 . If the temperature of the refrigerant at the outlet of the evaporator is higher than the boiling point, then we get an evaporator with overheating. Its magnitude ΔToverheat is the difference between the temperature of the refrigerant at the outlet of the evaporator (point 1) and its temperature on the saturation line AB (point 7):

ΔToverheat=T1 - T7

If points 1 and 7 coincide, then the temperature of the refrigerant is equal to the boiling point, and the superheat ΔToverheat will be equal to zero. Thus, we get a flooded evaporator. Therefore, when choosing an evaporator, a choice must first be made between a flooded evaporator and an evaporator with superheat.

Note that, under equal conditions, a flooded evaporator is more advantageous in terms of the intensity of the heat removal process than with overheating. But it should be taken into account that at the outlet of the flooded evaporator, the refrigerant is in a state of saturated vapor, and it is impossible to supply a humid environment to the compressor. Otherwise, there is a high probability of water hammer, which will be accompanied by mechanical destruction of the compressor parts. It turns out that if you choose a flooded evaporator, then it is necessary to provide additional protection for the compressor from the ingress of saturated steam into it.

If a superheated evaporator is preferred, then there is no need to worry about protecting the compressor and getting saturated steam into it. The probability of occurrence of hydraulic shocks will occur only in the event of a deviation from the required indicator of the magnitude of overheating. Under normal operating conditions of the refrigeration unit, the superheat value ΔToverheat should be in the range of 4-7 K.

When the overheating indicator decreases ΔToverheat, the intensity of the selection of heat from the environment increases. But at extremely low values ΔToverheat(less than 3K), there is a possibility of wet steam entering the compressor, which can cause water hammer and, consequently, damage to the mechanical components of the compressor.

Otherwise, with a high reading ΔToverheat(more than 10 K), this indicates that insufficient refrigerant is entering the evaporator. The intensity of heat removal from the cooled medium sharply decreases and the thermal regime of the compressor deteriorates.

When choosing an evaporator, another question arises related to the boiling point of the refrigerant in the evaporator. To solve it, it is first necessary to determine what temperature of the cooled medium should be provided for the normal operation of the refrigeration unit. If air is used as the cooled medium, then in addition to the temperature at the outlet of the evaporator, it is also necessary to take into account the humidity at the outlet of the evaporator. Now consider the temperature behavior of the cooled medium around the evaporator during the operation of a conventional refrigeration unit (Fig. 1a).

In order not to delve into this topic, we will neglect the pressure losses on the evaporator. We will also assume that the ongoing heat exchange between the refrigerant and environment carried out in a straight line.

In practice, such a scheme is not often used, since it is inferior to the counterflow scheme in terms of heat transfer efficiency. But if one of the coolants has a constant temperature, and the overheating readings are small, then the forward and counterflow will be equivalent. It is known that the average value of the temperature difference does not depend on the flow pattern. Consideration of the once-through scheme will provide us with a more visual representation of the heat exchange that occurs between the refrigerant and the cooled medium.

First, let's introduce a virtual value L, equal to the length heat exchange device (condenser or evaporator). Its value can be determined from the following expression: L=W/S, where W– corresponds to the internal volume of the heat exchange device in which the refrigerant circulates, m3; S is the heat exchange surface area m2.

If a we are talking about the refrigeration machine, the equivalent length of the evaporator is practically equal to the length of the tube in which the process takes place 6-1 . Therefore, its outer surface is washed by the cooled medium.

First, let's pay attention to the evaporator, which acts as an air cooler. In it, the process of taking heat from the air occurs as a result of natural convection or with the help of forced blowing of the evaporator. It should be noted that the first method is practically not used in modern refrigeration units, since air cooling by natural convection is ineffective.

Thus, we will assume that the air cooler is equipped with a fan that provides forced air blowing of the evaporator and is a tubular-finned heat exchanger (Fig. 2). Its schematic representation is shown in Fig. 2b. Let us consider the main quantities that characterize the blowing process.

Temperature difference

The temperature difference across the evaporator is calculated as follows:

ΔT=Ta1-Ta2,

where ΔTa is in the range from 2 to 8 K (for tubular-finned evaporators with forced airflow).

In other words, during normal operation of the refrigeration unit, the air passing through the evaporator should be cooled no lower than 2 K and no higher than 8 K.

Rice. 2 - Scheme and temperature parameters of air cooling on the air cooler:

Ta1 and Ta2– air temperature at the inlet and outlet of the air cooler;

  • FF– temperature of the refrigerant;
  • L is the equivalent length of the evaporator;
  • That is the boiling point of the refrigerant in the evaporator.

Maximum temperature difference

The maximum air temperature difference at the evaporator inlet is determined as follows:

DTmax=Ta1 - That

This indicator is used when selecting air coolers, since foreign manufacturers refrigeration technology provide values ​​for the cooling capacity of the evaporators Qsp depending on the size DTmax. Consider the method of selecting the air cooler of the refrigeration unit and determine the calculated values DTmax. To do this, we give as an example the generally accepted recommendations for selecting the value DTmax:

  • for freezers DTmax is in the range of 4-6 K;
  • for storage rooms for unpackaged products - 7-9 K;
  • for storage chambers for hermetically packed products - 10-14 K;
  • for air conditioning units - 18-22 K.

Degree of steam superheat at the outlet of the evaporator

To determine the degree of superheating of the steam at the outlet of the evaporator, use the following form:

F=ΔТoverload/DTmax=(Т1-Т0)/(Та1-Т0),

where T1 is the temperature of the refrigerant vapor at the outlet of the evaporator.

This indicator is practically not used in our country, but foreign catalogs provide that the readings of the cooling capacity of air coolers Qsp corresponds to the value F=0.65.

During operation, the value F it is customary to take from 0 to 1. Suppose that F=0, then ΔToverload=0, and the refrigerant leaving the evaporator will be in a saturated vapor state. For this model of air cooler, the actual cooling capacity will be 10-15% more than the figure given in the catalog.

If a F>0.65, then the cooling capacity indicator for this model of air cooler should be less value given in the catalog. Let's assume that F>0.8, then the actual performance for this model will be 25-30% more value given in the catalog.

If a F->1, then the cooling capacity of the evaporator Qtest->0(Fig. 3).

Fig.3 - dependence of the cooling capacity of the evaporator Qsp from overheating F

The process depicted in Fig. 2b is also characterized by other parameters:

  • arithmetic mean temperature difference DTср=Таср-Т0;
  • the average temperature of the air that passes through the evaporator Tasr=(Ta1+Ta2)/2;
  • minimum temperature difference DTmin=Ta2-To.

Rice. 4 - Scheme and temperature parameters showing the process of cooling water on the evaporator:

where Te1 and Te2 water temperature at the inlet and outlet of the evaporator;

  • FF is the temperature of the refrigerant;
  • L is the equivalent length of the evaporator;
  • That is the boiling point of the refrigerant in the evaporator.
Evaporators, in which the liquid acts as a cooling medium, have the same temperature parameters as for air coolers. The numerical values ​​of the temperatures of the cooled liquid, which are necessary for the normal operation of the refrigeration unit, will be different from the corresponding parameters for air coolers.

If the temperature difference across the water ΔTe=Te1-Te2, then for shell-and-tube evaporators ΔTe should be maintained in the range of 5 ± 1 K, and for plate evaporators, the indicator ΔTe will be within 5 ± 1.5 K.

Unlike air coolers, in liquid coolers it is necessary to maintain not the maximum, but the minimum temperature difference. DTmin=Te2-To- the difference between the temperature of the cooled medium at the outlet of the evaporator and the boiling point of the refrigerant in the evaporator.

For shell-and-tube evaporators, the minimum temperature difference DTmin=Te2-To should be maintained within 4-6 K, and for plate evaporators - 3-5 K.

The specified range (the difference between the temperature of the cooled medium at the evaporator outlet and the boiling point of the refrigerant in the evaporator) must be maintained for the following reasons: as the difference increases, the cooling intensity begins to decrease, and as the difference increases, the risk of freezing of the cooled liquid in the evaporator increases, which can cause its mechanical destruction.

Structural solutions of evaporators

Regardless of the method of using various refrigerants, the heat exchange processes occurring in the evaporator are subject to the main technological cycle refrigeration production, according to which refrigeration units and heat exchangers. Thus, in order to solve the problem of optimizing the heat exchange process, it is necessary to take into account the conditions for the rational organization of the technological cycle of refrigeration production.

As you know, cooling of a certain medium is possible with the help of a heat exchanger. Its constructive solution should be chosen according to the technological requirements that apply to these devices. A particularly important point is the compliance of the device with the technological process of thermal treatment of the medium, which is possible under the following conditions:

  • maintenance of the set temperature of the working process and control (regulation) of temperature regime;
  • choice of device material, according to chemical properties environment;
  • control over the duration of stay of the environment in the device;
  • compliance with operating speeds and pressure.
Another factor on which the economic rationality of the apparatus depends is productivity. First of all, it is affected by the intensity of heat transfer and compliance with the hydraulic resistance of the device. These conditions may be met under the following circumstances:
  • providing the necessary speed of working media for the implementation of the turbulent regime;
  • creation of the most suitable conditions for the removal of condensate, scale, frost, etc.;
  • creation of favorable conditions for the movement of working environments;
  • prevent possible contamination of the device.
Other important requirements are also low weight, compactness, simplicity of design, as well as ease of installation and repair of the device. To comply with these rules, factors such as: the configuration of the heating surface, the presence and type of baffles, the method of placing and fixing tubes in tube sheets, dimensions, arrangement of chambers, bottoms, etc.

The ease of use and reliability of the device are influenced by such factors as the strength and tightness of detachable connections, compensation for temperature deformations, ease of maintenance and repair of the device. These requirements form the basis for the design and selection of a heat exchange unit. The main role in this is to ensure the required technological process in the refrigeration industry.

In order to choose the right constructive solution for the evaporator, you must be guided by the following rules. 1) cooling of liquids is best done with a rigid tubular heat exchanger or compact plate heat exchanger; 2) the use of tubular-finned devices is due to the following conditions: the heat transfer between the working media and the wall on both sides of the heating surface is significantly different. In this case, the fins must be installed from the side of the lowest heat transfer coefficient.

To increase the intensity of heat transfer in heat exchangers, it is necessary to adhere to the following rules:

  • ensuring proper conditions for the removal of condensate in air coolers;
  • reduction of the thickness of the hydrodynamic boundary layer by increasing the speed of movement of the working bodies (installation of intertube baffles and breakdown of the tube bundle into passages);
  • improvement of the flow around the heat exchange surface by the working fluids (the entire surface must actively participate in the heat exchange process);
  • compliance with the main indicators of temperature, thermal resistance, etc.
By analyzing individual thermal resistances, you can choose the most best way increase the intensity of heat transfer (depending on the type of heat exchanger and the nature of the working fluids). In a liquid heat exchanger, it is rational to install transverse baffles only with several passes in the tube space. During heat exchange (gas with gas, liquid with liquid), the amount of liquid flowing through the annular space can be arrogantly large, and, as a result, the velocity indicator will reach the same limits as inside the tubes, due to which the installation of baffles will be irrational.

Improvement of heat exchange processes is one of the main processes for improving the heat exchange equipment of refrigeration machines. In this regard, research is being carried out in the field of energy and chemical engineering. This is the study of regime characteristics of the flow, flow turbulence by creating artificial roughness. In addition, new heat exchange surfaces are being developed to make heat exchangers more compact.

Choosing a rational approach for calculating the evaporator

When designing an evaporator, it is necessary to make a structural, hydraulic, strength, thermal and technical and economic calculation. They are performed in several versions, the choice of which depends on the performance indicators: technical and economic indicator, efficiency, etc.

To make a thermal calculation of a surface heat exchanger, it is necessary to solve the heat balance equation, taking into account certain operating conditions of the device (design dimensions of heat transfer surfaces, temperature change limits and schemes, relative to the movement of the cooling and cooled medium). To find a solution to this problem, you need to apply rules that will allow you to get results from the original data. But due to numerous factors, find common decision for different heat exchangers is not possible. Along with this, there are many methods of approximate calculation that are easy to produce in a manual or machine version.

Modern technologies allow you to choose an evaporator using special programs. Basically, they are provided by manufacturers of heat exchange equipment and allow you to quickly select the required model. When using such programs, it must be taken into account that they assume the operation of the evaporator at standard conditions. If the actual conditions differ from the standard, then the performance of the evaporator will be different. Thus, it is desirable to always carry out verification calculations the design of the evaporator you have chosen, in relation to the actual conditions of its operation.