Dzhileks compass pumps technical characteristics. What is a series of circulation pumps Compasses from the company Gileks? The main parameters of the pump Gileks Compasses

The scope of pumps Dzhileks Zirkul 25-40 are such engineering systems as heating and hot water supply. The task of the pump is to ensure the forced movement of the coolant (circulation). The Dzhileks Zirkul pump is successfully used in closed heating circuits and hot water supply systems.

Dzhileks Compasses 25-40 is a circular pump - a mandatory attribute of modern heating systems, air conditioning and ventilation systems, water supply and other engineering systems. The device is designed for forced movement of the coolant in closed air conditioning and heating systems, as well as for better recirculation hot water in systems providing supply hot water. Unlike other types of pumping equipment, circular pumps do not lift water and do not increase pressure in hydraulic systems, these devices are designed only to create circulation and only serve to move the coolant (liquid). The use of circular pumps Dzhileks Zirkul 25-40 allows you to speed up the process of heating heated rooms and achieve a uniform distribution of the temperature of the heat source throughout the heating system. The device requires a 220V mains supply.

The Compass series includes models with a three-speed electric motor and a wet rotor. Switching speeds is done manually: the higher the speed, the more powerful the pressure of the pump.

Circulation pumps Gilex can be adjusted to specific system parameters. Due to the high performance and the possibility of adjustment, the Dzhileks Zirkul 25-40 pumps can be installed in heating systems with smaller pipelines.

Dzhileks Zirkul pumps are capable of operating at temperatures environment up to 50°C, as well as at a coolant temperature from +10 to +110 degrees. The equipment has an IP 44 protection class. The pressure in the system, at which stable operation of the pump is ensured, should not exceed 1 MPa (10 bar).

The advantage of glandless circulation pumps is that they do not need to be centered during installation. All Jilex Compasses models have a low noise level (no more than 45 dB) and do not require Maintenance for many years.

Reading 5 min.

The circulation of the coolant in the heating system occurs due to circulation pumps. The pumps are designed for water that does not differ in drinking water properties.

The Gileks company, engaged in the production of pumping equipment, produces the Compass series, designed for heating systems.

Application and purpose

Gileks Compasses are circulation devices designed for heating and cooling, air-conditioned, ventilation systems. The purpose of the units is to circulate the working fluid in closed systems. When operating the apparatus, pipes of a smaller diameter are used than with natural circulation. Provide uniform distribution of temperatures in systems. The series of units features a wet rotor and a three-speed motor. The engine is equipped with a block for manually adjusting the speed of the working fluid in a closed system.

Gileks Compass provides heating of the heated room and uniform distribution over all parts of the working fluid circuit.

The presence of a wet rotor allows you to adjust the system. It features high performance, energy efficiency and low noise operation.

The lineup

The Jilex Compass series consists of six models with different characteristics.

Model numbers are deciphered in this way: the first digit is the rated power, the second is the pressure indicator.

Description of compasses models:

  • 25 40. Dzhileks Circulus 25 40 circulation pumps operate with a temperature range from ten to one hundred and ten degrees Celsius. Creates a pressure of four meters. Throughput three cubic meters per hour. Has three speeds. It is operated at room temperatures up to fifty degrees. Weighs three kilograms;
  • 25 60. The difference between the model and the previous one is in the generated pressure of six meters and throughput of 3.8 cubic meters per hour. Generates 65 dB noise;
  • 25 80. The model creates a maximum pressure of eight meters. Throughput of eight cubic meters per hour. Pumps Gileks Compasses 25 80 emit a noise of 45dB;
  • 32 40. The model of circulation pumps Dzhileks Compasses 32 40 is made of cast iron. Works with liquid temperatures up to one hundred and ten degrees Celsius. Circulation pumps Compass 32 40 have a rated power of 32 W, a pressure of four meters, a weight of 3600 grams, a hole diameter of 1.25 inches;
  • 32 60. The power of the model is 55 W, it creates a pressure of six meters, the throughput is 3.8 cubic meters per hour. Emits 45 dB noise;
  • 32 80. Pump model 32 80 The compass weighs six kilograms. The rated power of the device is 135 watts. Circulation pumps Dzhileks Zirkul 32 80 operate at three speeds. The maximum head and throughput are eight meters.

Design and application features

Compass devices have a number of features that distinguish them from other models and manufacturers.


Device features:

  • devices are characterized by high performance;
  • are applied to household systems of hot water supply and heating;
  • not to be used in potable water systems;
  • wet rotor for all models;
  • three-speed manual control motor;
  • works with water and liquids with ethylene glycol;
  • cast iron body, not subject to corrosion;
  • mounted horizontally and vertically;
  • lowering the rotation speed reduces the energy consumption and the volume of the device;
  • in the package there are nuts for mounting;
  • low vibration.

Characteristics of the circulation pump "Compass" Gileks (video)

Commissioning the pump

Before connection, the device is filled with water and air is pumped out. To release air, the bolt located on the back of the motor is rotated. Air bleeding will start. If water starts to flow out, then the air is deflated. The bolt returns to its original position. The valves on the suction and discharge sides open.

To switch the speed, use the speed switch located on the capacitor box.

Installation rules

  1. Installation is carried out in a ventilated warm room.
  2. Installation is carried out after welding and cleaning of the system.
  3. Shut-off valves are mounted at the inlet and outlet to the pump, this will prevent leakage and draining of water from the system when.
  4. To prevent damage, the device is installed above or near pipes.
  5. The device is connected to the pipeline in such a way that the axis of the incoming and outgoing pipes coincides.
  6. To ensure quiet operation and lack of vibration, the unit is not installed close to the knee.
  7. The diameter of the pipe must match the diameter of the unit;
  8. Installation is carried out so that the direction of the arrow on the device coincides with the direction of the working fluid;
  9. The unit is mounted taking into account accessibility to it if necessary.

Safety

Before dismantling or installing the unit, it is disconnected from the network. Before dismantling the device, wait for it to cool.

Protect the electrical parts during bleeding. To avoid damage, the pump is installed in a dry place.


The temperature range of the room is from minus ten to plus fifty degrees Celsius.

Gilex problems and how to fix them

Circulators are reliable, but there are minor problems. To eliminate them, you need to know the cause.

List of problems:

  • when starting, the unit stops immediately. The reason is plaque between the impeller and the housing. You can fix the problem by removing plaque and unlocking the shaft;
  • high noise level. The reason is air in the system or high water pressure. Troubleshoot by bleeding the system and reducing fluid velocity;
  • the unit does not start. The reason is that there is no voltage in the network, the capacitor has broken, the plaque on the bearings has blocked the shaft. It is necessary to check the integrity of the cable, unlock the shaft;

Subject to the rules of operation, the compass serves for many years and does not require.

Gileks Compasses are distinguished by reliability and quality. Positive reviews confirm the quality of the devices.

Circulation pumps are used for heating, air conditioning, water supply and ventilation systems. The units circulate fluid in the network. Due to this property, heat or refrigerant is distributed throughout the system, maintaining the temperature.

A trusted equipment manufacturer is Gileks, a company specializing in the production of pumping equipment. The brand of circulation pumps is called Dzhileks Zirkul.

1 Purpose

Dzhileks Compasses are applied to forced movement of liquid in system (heating, water supply, conditioning). The units do not have the functions of raising water to a height and increasing pressure. Devices are able to increase the speed of movement of the working fluid.

In heating systems, Dzhileks Compasses are used to move water from a heating boiler through a heating element into the system. This maintains and evenly distributes the temperature of the water in the circuit. Devices with more power are used in industry, with less power in domestic needs.

1.1 Model range

Depending on the section and pressure of the units, there is a division into models. Characteristics of the model ranges:


1.2 How to choose a device?

Selection sequence:

  • before proceeding with the selection of a circulation device, it is necessary to study information about them;
  • the second stage is the required section. The Gileks company produces mechanisms with two section sizes: these are thirty-two and twenty-five millimeters;
  • generated pressure. For pumps Compass, the indicator varies from three to eight meters. Therefore, each user will select the pump in accordance with the required indicators;
  • choice of rotor type. Devices with a dry type of rotor are characterized by an efficiency equal to 80 percent. However, they are not durable due to frequent overheating and breakdowns. A wet rotor has an efficiency of fifty percent. Such devices are suitable for private use and have a long service life.

1.3 Benefits of pumps

Gileks circulation pump has a number of advantages:

  1. Thanks to wet rotor, installation of the device does not require additional costs for pressure sensors and protective devices motor.
  2. Thanks to compactness, devices are mounted in any systems.
  3. The body material is selected in such a way that corrosion does not threaten the device.
  4. Aggregate availability. Units can be purchased at any professional store.
  5. Availability warranty period and service.

1.4 CHARACTERISTICS OF THE CIRCULATOR "CIRCUL" JILEX (VIDEO)

2 Installation

Installation rules and description:


2.1 How to deal with problems?

During operation, breakdowns occur that you can deal with yourself:

  • Noise at work. The reason is air entering the system or a rapid flow of fluid. To eliminate the air is removed or the flow rate is reduced;
  • the device does not turn on. The reason is the failure of the capacitor, the lack of voltage. To eliminate, the integrity of the cable and the voltage level in the network are checked;
  • after starting, the device stops. limescale- the cause of the problem. To eliminate, wash the device.

2.2 Mark recognition

Units differ in cross section and pressure. The first digit in the name of the model means the size of the section, the second - the pressure created. For example, circulation pumps Compass 32/40 have a cross section equal to 3 centimeters two millimeters, the pressure is four meters, and pumps Compass 32/80 has the same cross section, but the pressure creates eight meters.