Line of solid fuel and combined boilers ZOTA Smoke - M consists of four products with a capacity of 12, 18, 20, 25 kW and is designed for autonomous heating residential and industrial premises. Coal or wood is used as fuel for the basic model of the boiler, and in the combined version, electricity serves as an additional source of energy. The operating experience of solid fuel boilers set the main directions for modifications that were made to the design of the previously produced Dymok boiler.
The main differences between the new series and the previous one are the changes made to the design of the boiler water jacket. Reinforcing channels were installed, which made it possible to operate the boilers in systems with an operating pressure of up to 3 atmospheres and withstand a short-term increase in pressure up to 4 atmospheres, preventing deformation of the boiler walls. The geometry of the furnace space has changed - the furnace has become longer, which made it possible to use fairly long logs in the process of heating with firewood. This design change was caused by objective operating conditions: a huge number of domestic boiler houses consume firewood as fuel, therefore a deep furnace gives more convenience to the consumer. The gas duct system has changed - it has become removable and round for ease of installation of the boiler and is equipped with a step-adjustable damper. One of the main advantages and the most expensive modification of the boiler was the loading and ash doors of a new design. Now they are gas tight. Thus, the combustion process has become longer and the consumer has the opportunity to more accurately regulate it. This creates additional comfort, as temperature differences are smoothed out.
All boilers have a G2” threaded hole for installation of a heating element supplied with the boiler at the request of the consumer.
Boilers "Dymok - M" can be equipped with block heating elements with a capacity of 3 or 6 kW, made of stainless steel.
Using the control panel, the consumer sets the temperature of the air and the coolant in such a way that when the boiler cools down, the block-heater is automatically turned on and the heating system is constantly in operation. Despite the fact that the power of the block is less than the rated power of the boiler, the heating element allows you to maintain the system's performance even under the most low temperatures throughout the heating season.
As the main source of heat supply, select a solid fuel boiler with a margin to its rated power for longer operation on one load of fuel. At the same time, the safety of the boiler and the heating system as a whole must be ensured.

Table of technical characteristics of combined boilers ZOTA Dymok-M:

Name AOTV-12M AOTV-18M KOTV-20M AOTV-25M
Rated thermal power. kW 12 18 20 25
The volume of the water chamber of the device, l 30 53 56 65
Working pressure, atm, no more 3
Efficiency, % 70
Fuel coal, firewood
Overall dimensions, mm 645x480x615 750x396x702 750x400x705 835x446x702
Firebox depth 400 500 500 580
Connecting chimney size, mm 150
Weight, kg, no more 80 112 108 129

Operating time on one load

Up to 7 hours of continuous operation.

Operating pressure

Withstands a constant pressure of 3 atm.

Firebox parameters

Key Benefits

    Models "Dymok-M" 12, 18, 25 kW are equipped with a cast-iron stove with removable surfaces for more convenient loading of coal and heating food;

    A deep firebox will allow you to load firewood 410-580 mm long;

    Gas-tight loading and ash doors exclude the possibility of air penetration through the cracks. Thus, the fuel burns longer, and it becomes easier to control the combustion process with the air supply damper;

    In the boiler "Dymok-M" the water jacket is reinforced from the inside with channels ("P"-shaped profile). The design allows you to work in a system with pressure up to 3 atmospheres, without deformation of the boiler walls;

    Electricity can be used as an auxiliary heat source. To do this, stainless steel heaters (TEH) are installed in the boiler;

    The water jacket is located along the entire contour of the boiler, including under the ash pan. The design cools the ash box, prevents it from deforming, provides additional heat removal and improved circulation of the coolant.

Additional accessories

Delivery

For orders of any volume is available as a delivery service.

Delivery of most materials is carried out the next day.

Large orders are fulfilled during the week.

Delivery is carried out from a warehouse located at the intersection of 94 km of the Moscow Ring Road and the Yaroslavl Highway (Trakt-Terminal Trade and Construction Complex).
See the location map in the "Contacts" section.

The cost of delivery is calculated individually based on the volume of the order and mileage.

Delivery within the Moscow Ring Road - 1200 rubles, then - 35 rubles / km. One way mileage calculation. For example, 20 km from Moscow Ring Road = 1200 + 20 km x 35 rubles. = 1900 r.

Delivery is carried out to the entrance. Rise to the floor, skidding into the house and other work are paid separately(by agreement). It is advisable to warn about the need for these works in advance in order to agree on the cost and the required number of loaders.

* - The estimated cost of delivery is calculated, the final cost is determined after receiving the goods at the company's terminal.

Professional installation and installation of stoves, fireplaces, chimneys

Installation of a fireplace stove and chimney is a very important and at the same time individual issue. For an accurate assessment of the labor intensity and cost of work, as well as the elements of the chimney and thermal insulation materials necessary for the installation, it is necessary for the master to visit the site directly. The installer of fireplace stoves will be able to see with his own eyes what he has to do, and the client can discuss all the nuances of the installation.

Why is it necessary to call a measurer to the object as the first step?