Gas boiler kiturami turbo 30 lng. Overview of Kiturami diesel boilers - technical specifications. Strengths and weaknesses of diesel units

Kiturami Turbo 30r

Floor diesel double-circuit boiler Kiturami Turbo 30 for heating and hot water supply of residential premises up to 350 square meters.

Detailed description the purpose, application features and installation of Kiturami Turbo boilers are given on our website.

Advantages of diesel boilers Kiturami Turbo 30r

  • Large volume heat exchanger Kiturami Turbo 30r boiler allows you to provide a large amount of hot water
  • Powerful gear fuel pump , which ensures the operation of the boiler even when the fuel tank is up to 10 m from the boiler and its location is up to 2 m below the boiler level.
  • Possibility of connecting heating pipes on both sides of the boiler
  • Upgraded economy burner Kiturami Turbo (Kiturami Turbo), proportionally regulating fuel consumption depending on the set temperature of hot water and heating
  • Modern boiler safety system diesel dual-circuit kiturami Turbo 30 r, including sensors for low coolant level, overheating, flame control, air and gas pressure, room temperature)
  • Automatic boiler control system Kiturami Turbo 30, complete with a remote control panel, reliably supports the specified operating modes
  • built-in self-diagnosis system The Turbo 30r boiler identifies and displays faults, most of which can be corrected by the user without spending extra money on calling the service department.

Delivery set of the boiler Kiturami Turbo 30

The factory delivery set of the boiler includes: boiler with adjusted diesel burner TURBO - 30, room thermostat CTR 5700, fuel hoses, fuel filter, boiler certificate, brass fittings for connection to the main fuel line 1/2", plug for one of the heating outlets.

Characteristics of boilers Kiturami Turbo 30r



SUMMER PROMOTION - equipment at a discount (April-June)!

TOTAL DISCOUNT UP TO 10% WHEN ORDERING OTHER ACCESSORIES TOGETHER WITH THE BOILER(

Kiturami Turbo 30R is one of the models of floor-standing boilers, the main purpose of which is heating and hot water supply of both residential and industrial premises.

The described model performs its work at the expense of diesel fuel, therefore, such boilers are considered the most suitable for heating and hot water supply. The heat exchanger is made on the basis of such high-strength metal as steel. But this is not the main thing in which this model is superior to others.

The main advantages of the boiler Kiturami TURBO 30R

  • Profitability. The Kiturami Turbo 30R diesel boiler is very economical, due to the fact that eight liters are enough for daily fuel consumption. Also, high efficiency is achieved due to the turbocyclone burner, which is installed in the boiler. Thanks to it, maximum fuel efficiency is achieved, this is due to the aerodynamic flow in the zone where combustion occurs. This technology affects the increase in boiler efficiency;
  • Safety and reliability. The design of the boiler has special sensors that monitor temperature and overheating. Thus, the developers have fully provided the required control system;
  • Equipped with a self-diagnosis system. During operation, the consumer will not need to regularly check the equipment, since the system itself will produce defects and malfunctions that have arisen. You will learn about the existing errors in the work through the built-in display. So you will always be aware of the state of the boiler;
  • The convenience of use. The boiler comes with a remote control. With it, you can set all the necessary functions, no matter where you are (within the allowable distance). The remote control has a built-in thermostat, due to which it is possible to adjust the operation of the boiler according to the temperature indicators of the room.
  • It is possible to switch to another type of fuel. This requires a burner replacement;
  • Availability of hot water even in the non-heating period (summer). Due to the fact that the boiler is a boiler, it is able to produce the required amount of hot water. That is, for DHW there is no need for additional installations.

The technical characteristics of this boiler model include:

  • power 34.8 kW;
  • the volume of consumed fuel is 4.3 liters per hour;
  • the area allowed for heating is 350 square meters.

Diesel boilers Kiturami Turbo 30R is one of the economical and modern devices. The latest equipment allows you to effectively and cost-effectively use them as the main unit for heating and receiving hot water. When creating the Kiturami boiler, the developers took care of the reliability and durability of the equipment, including high-quality materials in its composition that perfectly protect it from the effects of corrosive processes. Would you like to find equipment for a long and efficient heating your house? Kiturami Turbo 30R is the most best option, combining unsurpassed quality, safety and long service life.

You can pick up the purchased goods yourself or use the delivery service in Moscow and the Moscow region. Having placed an order today, tomorrow you will receive it at your disposal. If necessary, you can use the service of prompt delivery and receive products today.

Delivery to the entrance (check with the manager about the possibility of raising to the floor)

Delivery is made daily from 9 am to 9 pm including weekends and holidays.

Specify exact terms of delivery at the manager!

Pickup points

Delivery cost in Moscow and the Moscow region:

  • Within the Moscow Ring Road - from 0 to 500 rubles, (Individual shipping cost is indicated in the product card)
  • Outside the Moscow Ring Road up to 10 km - 700 rubles,
  • Outside the Moscow Ring Road further 10 km - 700 rubles + 30 rubles for each kilometer.
  • In the regions, delivery by a transport company (calculated individually).

Shipping cost for

km from MKAD

700 rub.

Unloading of bulky goods is carried out by the forces and means of the customer.

Money is transferred directly to the courier upon receipt of the goods. This method is the most popular among buyers due to the simplicity and ease of calculation.

Payment bank card courier upon receipt

Couriers have a portable bank terminal available, which allows Teplovod-Service customers to pay for goods with bank plastic cards (check with the manager about the possibility of paying with a bank card).

Payment by credit card on the site

To select payment by bank card on the "Cart" page, select the item "Payment by bank card on the site".

Payment is made through PJSC SBERBANK using Bank cards of the following payment systems:


After clicking on the "ONLINE PAYMENT" button, you will be redirected to the payment gateway of Sberbank of Russia OJSC to enter your card details.

Please prepare your plastic card in advance. Additionally, you need to enter the full name, email, contact phone number, as well as the reservation number to identify the payer. The connection with the payment gateway and the transfer of information is carried out in a secure mode using the SSL encryption protocol.

If your bank supports the technology of secure online payments Verified By Visa or MasterCard Secure Code, you may also need to enter a special password to make a payment. You can check the methods and the possibility of obtaining passwords for making Internet payments at the bank that issued the card.

This site supports 256-bit encryption. Privacy Reported personal information provided by OJSC "Sberbank of Russia". The entered information will not be provided to third parties, except as provided by the legislation of the Russian Federation. Payments by bank cards are carried out in strict accordance with the requirements of Visa Int payment systems. and MasterCard Europe Sprl.

When paying by credit card, interest is not charged.

Payment is a transfer of funds from the buyer's current account to the seller's account, we work on a common taxation system with VAT. Delivery of goods is carried out after the receipt of funds to the account of the company "Teplovod-Service". This method is used in the calculations of legal entities.

Our details

    Limited Liability Company "Teplovod-Service"

    OGRN: 1105003006162

    TIN: 5003088884

    Checkpoint: 500301001

    BIC: 044525225

    Bank: PJSC Sberbank of Russia

    R/s: 40702810838060011732

    K/s: 30101810400000000225

    Jur. the address: 142718, Moscow region, Leninsky district, Bulatnikovskoe rural settlement, Varshavskoye highway, 21 km., office B-6

Special conditions

    For goods with the status "On order" worth up to 100,000 rubles. no prepayment required.

    For goods with the status "On order" over 100,000 rubles. a 30% deposit is required.

  • For any goods sent by a transport company, 100% payment is required.

I was looking for a used backup diesel boiler. My main heating closes on electricity and a fireplace with a water jacket Optima Aqua 700Sh. Diesel is needed to support TA in very coldy and in case of a power outage (connected via an uninterruptible Smart UPS 3000VA).

There are few offers on the secondary market, starting from 15 tr. (at the price of a new 30 tr.), but occasionally there are offers for 10 tr. Most often, happy homeowners who have been supplied with gas get rid of diesel boilers. Therefore, the condition of the boilers is quite good, they have worked for 1-2 seasons.

And then one day I turned up Kiturami Turbo 30R (35 kW) for 7 tr. I examined it and bought it. I brought it home, tied it to CO, put a 200l plastic fuel barrel, replaced the fuel filters and 1 fuel line hose.

The boiler began to give error 01 at startup. Error 01 means that there is no ignition of the fuel. I rummaged through the Internet and formulated "troubleshooting", i.e. how to solve this problem step by step:

  1. We check the voltage in the network. The voltage should be standard 220-230 V ().
  2. Checking the fuel line. There must be no air leakage at the fuel supply to the fuel pump of the boiler.
  3. We check the fuel filter. The fuel filter may be clogged, making it difficult to supply fuel in the proper amount. If clogged, replace the fuel filter.
  4. We check that the fuel does not flow by gravity (relevant for boilers 21R, 30R).
  5. Possibly poor fuel quality. Change the fuel, or try to close the choke and apply a richer mixture. The damper is located on the left end of the burner (see diagrams below).
  6. We check the flame control sensor (photocell). The sensor can be pulled out of the burner body by turning it along the axis (see diagrams below). Wipe clean with a dry cloth, the protective cover from the end should be perfectly transparent. If the front cover is removed, the photocell may react to extraneous light and give an error.
  7. We check, clean (or change) the nozzle and ignition electrodes. They can be reached by removing the entire burner from the combustion chamber flange (see diagrams below).
  8. We check the operation of the ignition transformer. It should give a spark to the ignition electrodes (I don’t know how to check the spark, I haven’t reached this stage of troubleshooting).
Schemes of burners for diesel boilers Kiturami Turbo 13R, 17R:

Schemes of burners for diesel boilers Kiturami Turbo 21R, 30R:

I stopped at stage 5. He covered the air damper with his hand and the boiler started up. Obviously, the turbine simply blew diesel fuel into the combustion chamber with such force that the electrodes simply could not ignite it. Excess fuel after stopping the boiler with error 01 seeped through the burner flange. Using the method of scientific poke, I adjusted this damper so that the boiler starts at the next cycle without error.

The problem that I have not yet been able to overcome is condensation in the chimney. During a cold start, there was so much of it that a sickly puddle flowed onto the floor. It flowed both through the chimney steam trap and through the elbow that comes from the boiler.

  • High efficiency due to 3-PASS design
  • Low Noise Boiler
  • DHW heat exchanger made of stainless steel
  • Stable hot water in large volume
  • Built-in turbo cyclone burner
  • Compact and easy installation

Safety, convenience and customer satisfaction have been the main goal of KITURAMI for 40 years!

To increase the efficiency of boilers Kiturami (KITURAMI) TURBO, the design of multiple passage of combustion products inside the heat exchanger is used.

The KITURAMI TURBO boiler has the "Absence", "Shower", "Sleep" functions, which can significantly reduce fuel consumption. As well as the presence of safety devices such as a low water level sensor, overheating and other devices will ensure complete safety when using the boiler.

The design of multiple passage of combustion products inside the heat exchanger increases efficiency, and also reduces the level of acoustic noise.

Thanks to the stainless steel DHW heat exchanger, scale formation is prevented and clean hot water is provided.


The turbocyclone burner achieves the highest combustion efficiency thanks to a special plate (FCH₂) heated up to 800°C, thus reducing fuel consumption.

The capacitive heat exchanger of the heating circuit of the Kiturami TURBO boiler allows you to almost instantly get hot water from the DHW circuit.

The Kiturami (KITURAMI) TURBO boiler does not require a lot of space for its installation, and is also easy to carry.

Model of boilers Kiturami (Kiturami) Turbo

13R

17R

21R

30R

Heating capacity/DHW

Average consumption of diesel fuel for the heating season

Hot water capacity

dT=25°C

dT=40°C

Heat exchanger area

Heat exchanger capacity

Pipe diameter

heating input/output

DHW inlet/outlet

chimney

Width

Length

Height

Weight

Consumed e. energy